Dimensions and connections

Fig.104
Dimensions and connections
1
2
3
4
1 Condensate discharge
2 Domestic hot water outlet G 3/4"
3 Domestic cold water inlet G 3/4"
Description
A
Diameter of the water heater
B
Height of the water heater
C
Height cold water connection
D
Height hot water connection
E
Height drain opening
F
Height condensates discharge opening
7659610 - v02 - 08032017
Note
The values in tonnes of CO
following formula: quantity (in kg) of refrigerant fluid x GWP /
1000.
GWP = Global Warming Potential. The GWP of R-134a is 1430.
Note
R-134a refrigerant is contained in equipment that has been her­
metically sealed.
A
5
6
7
For more information, see
Location of the water heater, page 202
3 Technical specifications
equivalent are calculated using the
2
B
F
4 Drain opening
5 Magnesium anode
6 Shielded 1.55 kW immersion heater
Unit
ETWH 180 E
mm
552
mm
1670
mm
240
mm
1050
mm
93
mm
1308
en
D
C
E
ETWH 230 E
552
1990
240
1370
93
1628
193