Connection
7.7

DC-Kit3/DC-Kit5 with Dometic B1600/HB2500

 Air conditioner:
– Roof air conditioner: Dometic B1600
– Under-bench air conditioner Dometic HB 2500
 Circuit diagram: fig. 0, page 12 (12 V), fig. f, page 18 (24 V)
 Charging current distributor: ECL-102/ECL-103
 Inverter: SinePower MSI1812T/MSI1824T
➤ Install inverter remote control MCR9 in an easily-accessible place (jumper closed, refer
to remote control installation manual) and connect its cable to the inverter.
➤ Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
➤ Use the blue wire of the universal connection cable (item no. 4441300124) to join the I5
connection of the ECL-102/ECL-103 to the MCR9 remote control (use wire sleeves).
➤ Use the brown wire of the universal connection cable to join the D+ input to the
I2 connection on the ECL-102/ECL-103 (use wire sleeves).
7.8
DC-Kit3/DC-Kit5 with Dometic FreshJet1100/1700/2200,
FreshLight1600/2200
 Roof air conditioner:
– Dometic FreshJet1100/1700/2200
– Dometic FreshLight1600/2200
 Circuit diagram:
– Dometic FreshJet1100/1700/2200:
fig. a, page 13 (12 V), fig. g, page 19 (24 V)
– Dometic FreshLight1600/2200:
fig. b, page 14 (12 V), fig. h, page 20 (24 V)
 Charging current distributor: ECL-102/ECL-103
 Inverter: SinePower MSI1812T/MSI1824T
➤ Install inverter remote control MCR9 in an easily-accessible place and connect its
cable to the inverter.
➤ Remove the FreshJet/FreshLight's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the FreshJet1100/1700/2200 or FreshLight1600/2200 to the
plug connector on the circuit board (fig. r, page 29 for FreshJet and fig. s, page 29
for FreshLight).
I
NOTE
Guide the on/off cable carefully past the fan.