Herunterladen Inhalt Inhalt Diese Seite drucken

Dc-Kit2 With Dometic B1600/Systems With Enable Input - Waeco ECL-102 Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ECL-76, ECL-102, ECL-103
Dometic B1600 Plus/B2200
I
NOTE
B2200 with a serial number lower than 802200001 must be installed as
described in chapter 7.4.
➤ Remove the B1600 Plus/B2200's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the B1600 Plus/B2200 (item no. 4441300129) to the plug
connector on the circuit board (fig. t, page 30).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B1600 Plus/B2200.
7.4

DC-Kit2 with Dometic B1600/Systems with enable input

 Roof air conditioner:
– Dometic B1600
– Systems with enable input approved by the manufacturer
 Circuit diagram: fig. 4, page 6
 Charging current distributor: ECL-102
 Inverter: PerfectPower PP2002
➤ Install the switch, which is connected to the two-wire cable, in an easily-accessible
place.
➤ Connect the system plug to the inverter. Divide a wire of the cable in such a way that
the ends produced can be connected to the I2/l3 connectors of the ECL-102 with wire
sleeves. If necessary, extend the wires with a suitable cable.
EN
Connection
107