Starterpaket
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

• Format:
XXyyyyyy#
XX =
yyyyyy =
# =
e. Memorize frequently bypassed zones ("HOME" mode)
• HOME mode is only available for use with USER CODE 3 (whole system). However, partitions
can be bypassed by bypassing the zones within the partition one by one.
• Zone 8 (24 hour zone) is excluded from use in HOME mode
• Format:
HOMEyyyyyy#
HOME
yyyyyy =
# =
• To use the home mode, simply type USER CODE 3,
automatically be bypassed.
f. Keypad audible notification set-up
• Some audible notification can be passed on to the keypad. This is the case for the exit and entry
delay, after an alarm condition and for each key button press.
• Alarm conditions concerning battery low or AC power failure conditions are always ON.
• Passing these notifications through to the keypad will not affect the beep settings on the master
control unit.
• Note that confirmation beeps from the
14yyyy#
14
yyyy =
# =
g. Alarm detection response time
The default zone response time is set to 500ms. This setting can be adjusted independently per
zone, depending on the conditions in that zone.
The 8 digit code represents the 8 protection zones. The first digit is zone 1 and the last digit is
zone 8. By putting the timing codes into the specific digit to independently the desired response
time can be set.
15yyyyyyyy#
14
yyyyyyyy =
# =
h. Reset system to default
To reset the system to its default values, enter code 2100#.
Except for the master code, all other values will be cleared or set to their default.
00 (10/10/2008)
HAM263D
11
USER CODE 1 for arm/disarm control of part. 1
12
USER CODE 2 for arm/disarm control of part. 2
13
USER CODE 3 for arm/disarm control of the
whole system (partition 1 and 2)
4 to 6 digits
validation
Press HOME button on keypad
List of zones to be enabled, sequential e.g. 245 to
bypass zones 2, 4 and 5
validation
-button and
master code
4 digits: 0=beep disabled, 1=beep enabled (default)
digit 1
Beep for exit delay
digit 2
Beep for entry delay
digit 3
Beep after alarm condition
digit 4
Beep after each key button press
validation
master code
8 digits, default setting = 3
1
25 ms
2
250 ms
3
500 ms
4
750 ms
validation
16
and
; all programmed zones will
-button are always enabled.