Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman HAM263D Bedienungsanleitung Seite 15

Starterpaket
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Audible keypad notifications
1 short beep
2 short beeps
5 short beeps
1 long beep
1 short beep/30 seconds
• Continuous short beeps at 0.5
second interval
• Beeping increases to 4 beeps/second
at the last 10 seconds
1 long beep at the end of the period
4 short beeps with 1 second interval
5.5
Programming
a. Set programming mode
a.
Make sure the system is in disarmed mode and the alarm memory is empty.
b.
Enable programming mode with the master code. Key in the master code, followed by
The system generates 2 beeps for successful and 5 beeps for unsuccessful code entry.
c. Factory default master code is 1234. For security reasons, it is strongly advised to replace this
master code with a personal code.
d.
The PROGRAM LED is on and the system stops all its detection activities.
e.
In case the master code is forgotten, use the following procedure to enable programming
mode:
i. Switch off both AC and battery power for at least one minute.
ii. Switch power back on. This will bring the system in standby mode for one minute. The
AC power and the battery LED flash alternately, and short beeps are heard.
iii.
During standby mode, key in code 8080, followed by
Note: this procedure will only work during standby mode after power-up.
b. Start programming
After the system is set to programming mode, the available options can be set. It is not necessary
to follow a certain sequence; jumping to any available programming location is possible.
Every programming code consists of three parts: the location, the value and the validation. These
are entered sequentially without any characters in between:
XXyyyyyy#
XX =
yyyyyy =
# =
c. Record a master code
• The master code is the authorization code for setting the system in programming mode.
• It can consist of 4 to 6 digits.
• After entering a new master code, the old one is erased.
• Format:
01yyyyyy#
01
yyyyyy =
# =
d. Record a user code
• It can consist of 4 to 6 digits.
• After entering a new user code, the old one is replaced.
• To remove a user code, key in the location, immediately followed by #.
00 (10/10/2008)
HAM263D
Successful key entry
Successful code entry for a specific function
• Unsuccessful code entry
Code entry time expired (Maximum Allowable
Time:10 seconds/digit, 60 seconds/code)
Exit delay expired, system is armed
Battery low or AC power failure
During the Exit delay, Entry delay and System
Standby period
After an alarm condition before the system is
disarmed
Location in memory
value
validation
master code
4 to 6 digits
validation
15
.
VELLEMAN
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis