Dual DIP switch:
Switch 1
Switch 2
ON
OFF
OFF
ON
OFF
OFF
The termination is appropriate for cables with an impedance of approx.
115 ohm. For cables not matching this value an external termination with
appropriate impedance is required. This interface module supports all
data rates up to 10 Mbit/s.
Important: To maintain the electro-magnetic compatibility (EMC) the
shield of the cable connected to the D-sub DE9M plug must be solidly
attached to the screen of the connector.
Pin assignment is compatible to all RS-485 interfaces by SOHARD.
Connector type: 9 pin D-sub female
Pin assigment
24
ON
Line termination for RS485
active
Line termination for RS485
inactive
Invalid
ON
Invalid
Pin
1,5
3
4
2, 6-8
9
Shield
Function
Marking
Description
GND_RS Reference potential,
supply
DATA-A
Data line A
DATA-B
Data line B
NC
reserved
+5V_RS
Isolated +5V Supply for
RS485 Interface. The
maximum current must
not exceed 25 mA.
AGND
Shield
Remarks