Herunterladen Inhalt Inhalt Diese Seite drucken

Grundig XENARO GDP 5100 Serviceanleitung Seite 30

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Platinenabbildungen und Schaltpläne / Layout of PCBs and Circuit Diagrams
WM8736
SCKI
ML/I2S
(2)
(12)
256fs
384fs
512fs
WM8736
BCKIN (3)
LRCIN (4)
SERIAL
DIGITAL
DIN0 (5)
INTERFACE
FILTERS
DIN1 (6)
DIN2 (7)
(24)
(20)
(11)
AGND2
AGND1
DGND
PIN NAME
TYPE
1
DVDD
Supply
2
SCKI
Digital input
3
BCKIN
Digital input
4
LRCIN
Digital input
5
DIN0
Digital input
6
DIN1
Digital input
7
DIN2
Digital input
8
MODE
Digital input
9
MUTE
Digital I/O
10
RSTB
Digital input
11
DGND
Supply
12
ML/I2S
Digital input
13
MC/IWL
Digital input
14
MD/DM
Digital input
15
AVDD1
Supply Analogue
16
CAP
Analogue output
17
OUT2L
Analogue output
18
GR2
Analogue input
19
OUT2R
Analogue output
20
AGND1
Supply Analogue
21
OUT1L
Analogue output
22
GR1
Analogue input
23
OUT1R
Analogue output
24
AGND2
Supply
25
OUT0L
Analogue output
26
GR0
Analogue input
27
OUT0R
Analogue output
28
AVDD2
Supply
ML6429
*CAN ALSO INPUT SYNC ON GREEN SIGNALS
CV INF /Y1*
FILTERED CHANNEL
2
REQUIRED
SYNC STRIP
SYNC
TIMER
SYNCIN
23
SYNCOUT
SYNC
24
TIMER
CV INU A/Y2*
3
MUX
CV INU B/Y3*
4
TRANSCONDUCTANCE
R IN A/Y4
ERROR AMP
7
MUX
R IN B/Y5
8
TRANSCONDUCTANCE
ERROR AMP
G IN A/Y6
9
MUX
G IN B/Y7
10
TRANSCONDUCTANCE
ERROR AMP
B IN A/C1
11
MUX
B IN B/C2
12
TRANSCONDUCTANCE
ERROR AMP
A/ B MUX
1
CONTROL
A/BMUX SWAP CVF SWAP CVU CV
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
3 - 6
MC/IWL
MD/DM
MODE
RSTB
MUTE
(13)
(14)
(8)
(9)
(10)
CONTROL INTERFACE
SIGMA
MUTE/
STEREO
DELTA
ATTEN
DAC
MODULATOR
SIGMA
MUTE/
STEREO
DELTA
DAC
ATTEN
MODULATOR
SIGMA
MUTE/
STEREO
DELTA
ATTEN
DAC
MODULATOR
(16)
(28)
(15)
(1)
CAP
AVDD2
AVDD1
DVDD
DESCRIPTION
Digital positive supply
System clock input (256, 384 or 512fs)
Audio data bit clock input
Left sample rate clock input
Channel 0 serial audio data input
Channel 1 serial audio data input
Channel 2 serial audio data input
Mode select pin; Low is software mode, high is hardware control; Internal pull-down
Mute control pin, input or automute output; Low is not mute, high is mute, Z is automute
Reset input •active low; Internal pull-up
Digital ground supply
Latch enable (software mode) or input format selection (hardware mode); Internal pull-up
Serial control data clock input (software mode) or input word length selection (hardware mode); Internal pull-up
Serial control data input (software mode) or de-emphasis selection (hardware mode)
positive supply
Analogue internal reference
Left channel 2 output
Channel 2 reference
Right channel 2 output
ground supply
Left channel 1 output
Channel 1 reference
Right channel 1 output
Analogue ground supply
Left channel 0 output
Channel 0 reference
Right channel 0 output
Analogue positive supply
17
22
6
V CCO RGB
V CCO CV
V CC
4th-ORDER
FILTER
+
0.5V
TRANSCONDUCTANCE
ERROR AMP
ML6429
SWAP
MUX
+
0.5V
4th-ORDER
FILTER
+
0.5V
4th-ORDER
FILTER
+
0.5V
4th-ORDER
FILTER
+
0.75V
IN – OUT
1/Y
A CV
2/Y
B
R
/Y
OUT
OUT
OUT
OUT
OUT
OUT
CV
/Y1
CV
B/Y3
R
B/Y5
INF
INU
IN
CV
/Y1
CV
/Y1
R
B/Y5
INF
INF
IN
CV
B/Y3
CV
B/Y3
R
B/Y5
INU
INU
IN
CV
B/Y3
CV
/Y1
R
B/Y5
INU
INF
IN
CV
/Y1
CV
A/Y2
R
A/Y4
INF
INU
IN
CV
/Y1
CV
/Y1
R
A/Y4
INF
INF
IN
CV
A/Y2
CV
A/Y2
R
A/Y4
INU
INU
IN
CV
A/Y2
CV
/Y1
R
A/Y4
INU
INF
IN
DVDD
1
SCKI
2
BCKIN
3
LRCIN
4
DIN0
5
(27) OUT0R
DIN1
6
(26) GR0
DIN2
7
(25) OUT0L
WM8736
MODE
8
(23) OUT1R
(22) GR1
MUTE
9
(21) OUT1L
RSTB
10
(19) OUT2R
DGND
11
(18) GR2
(17) OUT2L
ML/I2S
12
MC/IWL
13
MD/DM
14
14
13
SWAP CVF
SWAP CVU
A/ B MUX
CV INF /Y1
CV INU A/Y2
CV INU B/Y3
CV OUT 1/Y OUT A
2
21
GND
CV OUT 2/Y OUT B
2
20
V CC
R IN A/Y4
R OUT /Y OUT C
R IN B/Y5
2
18
G IN A/Y6
G OUT /Y OUT D
G IN B/Y7
2
16
B IN A/C1
B IN B/C2
B OUT /C OUT
2
15
GNDO
GND
19
5
C
G
/Y
D
B
/C
OUT
OUT
OUT
OUT
G
B/Y7
B
B/C2
IN
IN
G
B/Y7
B
B/C2
IN
IN
G
B/Y7
B
B/C2
IN
IN
G
B/Y7
B
B/C2
IN
IN
G
A/Y6
B
A/C1
IN
IN
G
A/Y6
B
A/C1
IN
IN
G
A/Y6
B
A/C1
IN
IN
G
A/Y6
B
A/C1
IN
IN
Xenaro – GDP 51..., GDP 6150
28
AVDD2
27
OUT0R
GR0
26
OUT0L
25
AGND2
24
23
OUT1R
22
GR1
21
OUT1L
AGND1
20
OUT2R
19
GR2
18
OUT2L
17
CAP
16
AVDD1
15
1
24
SYNCOUT
2
23
SYNCIN
3
22
V CCO CV
4
21
CV OUT 1/Y OUT A
5
20
CV OUT 2/Y OUT B
6
19
GNDO
ML6429
7
18
R OUT /Y OUT C
8
17
V CCO RGB
9
16
G OUT /Y OUT D
10
15
B OUT /C OUT
11
14
SWAP CVF
12
13
SWAP CVU
GRUNDIG Service

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis