Technical Data; Accessories - Riello RS 50/M Typ 30965 Serie Installations-, Bedienungs- Und Wartungsanleitung

Zweistufig gleitender oder modulierender betrieb
Inhaltsverzeichnis

Werbung

TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
OPERATING CURRENT
START-UP CURRENT
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m s.l.m.
(2) Pressure at test point 7)(A)p.12, with zero pressure in the combustion chambre, an maximum burner output.
(2) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output, and measured from a dis-
tance of one meter.
VARIANTS:
Blast tube lenght mm

ACCESSORIES

(optional):
• KIT FOR LPG OPERATION: The kit allows the RS 50/M burner to operate on LPG.
Output kW
Code
• KIT FOR MODULATING OPERATION
OUTPUT POWER REGULATOR KIT RWF40
Two components should be ordered:
• the Output power regulator to install on the burner;
• the Probe to install on the heat generator
Parameter to control
Adjustment field
Temperature
- 100...+500°C
0...2.5 bar
Pressure
0...16 bar
• POTENTIOMETER KIT FOR THE INDICATION OF LOAD POSITION: code 3010109
IMPORTANT:
The installer is responsible for the addition of any safety device not forseen in the present manual.
kW
MAX.
Mcal/h
kW
MIN.
Mcal/h
kWh/Sm
Mcal/Sm
kg/Sm
3
Sm
mbar
°C
°C max
V
Hz
rpm
W
V
A
A
V1 - V2
I1 - I2
W max
dBA
261 - 351
Probe
Type
PT 100
Output probe
4...20 mA
GAS NATURAL: G23 - G25
3
3
3
/h
• Intermittent (min. 1 stop in 24 hours)
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water. steam. diathermic oil
0 - 40
60
3 ~ 400V / 230 V 1N ~ 230V +/-10%
50 Hz
89/336 - 2004/108 - 73/23 - 2006/95 - 2006/42
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
80 - 630
20008173
Output power
regulator
Code
Type
3010110
3010213
RWF40
3010214
10
RS 50/M
26653X 30965X
285 - 630
245 - 542
80
69
G20
G25
9.45
8.13
8.2
7.0
0.71
0.78
66.5
77.5
8.5
11.3
2800
650
220/240 - 380/415
3 - 1.7
13.5 - 7.7
230 V - 1x8 kV
1 A - 20 mA
750
IP 44
72
CATEGORY
II
2H3B/P
II
II
NL
2L3B/P
II
FR
II
DE
2ELL3B/P
I
BE
2E(R)B,
II
LU
2E3B/P
Code
3010212
GB
2H3P
2Er3P
I
3P