ATTIX 130
- Before emptying the container it is a advisable to clean
the filter (see "Shaking the main filter" sect.).
a) Normal version, not suitable for treating hazardous
dust
- Release the container "I" (fig. 9), then remove and
empty it.
- Make sure that the seal is in perfect condition and
correctly positioned.
- Place the container back in position and use the lever
to secure it again.
Plastic liner
A plastic liner (our code 40100) can be used to collect
dust (see fig. 9).
In this case, the machine must be equipped with optional
accessories (grill and depressor - fig. 9).
b) Versions for dusts that are hazardous for the health.
Classes M - H, suitable for vacuuming hazardous
and/or carcinogenic dust.
ATTENTION DANGER !
- In compliance with current laws, these operations
can only be carried out by trained and specialized
personnel who must wear adequate clothing.
- Take care not to raise the dust during this operation.
Wear a P3 protective mask.
- A plastic liner can be used (our code 40100) or
ABS safety container (our code 8 30202 - 8 31685)
if dust that is dangerous and/or hazardous for the
health must be removed.
- The container and/or liner must only be disposed
of by trained personnel and in compliance with the
GB
current laws in force.
How to replace the safety container
- Place the hose in a safe, dust-free place;
- release the dusts container "I" (fig. 10);
- close the safety container with the supplied cover and
remove it from the dusts container "I" (fig. 10). Fit an
empty container in its place.
- Start the motor again to prevent dust from being blown
about.
C319
- Make sure that the seal is in perfect condition and
correctly positioned.
- Switch off the motor, fit an empty drum in place and
fasten it in position.
Use as a wet cleaner
Make sure that the vacuum cleaner is equipped with a
float (liquid level sensor) and is suitable for use as a wet
cleaner.
Do not clean up flammable liquids.
If foam forms, stop work immediately and empty the
container.
The filter element will be wet after liquids have been
cleaned up.
A wet filter element can quickly become clogged if the vac-
uum cleaner is then used to clean up dry substances.
For this reason, make sure that the filter element is dry
or replace it with another one before using the vacuum
cleaner to clean up dry materials.

- At the end of a cleaning session

1 - Turn off the vacuum cleaner and remove the plug
from the socket.
2 - Coil the connection flex (fig. 11).
3 - Empty the container as described in the "Emptying
the container" section. Clean the vacuum cleaner
as described in the "Maintenance, cleaning and
decontamination" section.
4 - Wash the container with clean water if aggressive
substances have been cleaned up.
5 - Store the vacuum in a dry place, out of the reach of
unauthorized people.
6 - Shut the inlet with the appropriate plug "A" (fig. 11)
when the vacuum cleaner is transported or not being
used (particularly in the case of versions M - H).

- Maintenance, cleaning and decontamination

ATTENTION DANGER !
Note: the precautions described below must be taken
during all the maintenance operations, including
cleaning and replacing the main and Hepa filters.
a) To allow the user to carry out the maintenance
operations, the vacuum must be disassembled,
cleaned and overhauled as far as is reasonably
possible, without causing hazards for the main-
tenance staff or other people.
8