- Dimensions (fig. 3)
ATTIX 130
Model
ATTIX 130 L, M, H
(60 L)
A (mm)
650
B (mm)
800
C (mm)
1400
- Controls and indicators (fig. 4)
A - Vacuum gauge
B - Switch button
C - Lighted mains voltage indicator
D - Lighted filter clogging indicator
E - Service socket

- Inspections prior to starting

Prior to starting, check that:
- the filters are installed;
- all latches are tightly locked;
- the hose and tools have been correctly fitted into inlet
"A" (fig. 5);
- the bag or safety container are installed, if applica-
ble.
- Do not use the vacuum cleaner if the filter is faulty.

- Starting-up

- Lock the castor brakes "E" (if present) before starting
the vacuum cleaner (fig. 6);
- press the buttons "B" - fig. 4.

- Operation

Check the flow rate:
- when the vacuum cleaner is operating, the pointer of
the vacuum gauge ("A" - fig. 7) must remain in the green
zone (OK) to ensure that the speed of the intaken air
does not drop below the safety value of 20 m/sec;
- if the pointer is in the red zone (STOP), it means that
the speed of the air in the hose is below 20 m/s and
that the vacuum cleaner is not working in safety condi-
tions - clean or replace the filters;
- when the hose is blocked, the pointer of the vacuum
gauge must switch from the green zone (OK) to the
red zone (STOP).
07/2008
ATTIX 130
If the vacuum cleaner is Class M or H, only use hoses
ATTIX 130 L, M, H
with diameters that comply with the indications in the
(100 L)
"Technical Specifications" Table in order to prevent
650
the air speed from dropping below 20 m/sec.
800
1600
When the vacuum cleaner is operating, always check
to make sure that the vacuum gauge pointer remains
in the green zone (OK).
Consult the "Troubleshooting" chapter if faults
occur.

- Shaking the main filter

Depending on the quantity of dust cleaned up, shake
the main filter by means of the lever " J" (fig. 8) when the
vacuum gauge pointer ("A" fig. 8) switches from the green
zone (OK) to the red zone (STOP).
Stop the machine before shaking the filter.
Do not shake the filter whilst the machine is on as
this could damage the filter itself.
Wait before restarting the vacuum cleaner, to allow the
dust to settle.
Replace the filter element if the pointer still remains in the
red zone (STOP) even after the filter has been shaken
(consult the "Main filter replacement" section).

- Stopping - emergency stopping

Press the push-buttons "B" (fig. 4).

- Emptying the container

Turn off the machine and remove the plug from
the power socket before proceeding with this ope-
ration.
Check the Class of the vacuum cleaner.