Connections LSIS 120....................12 5.1 LSIS 122........................12 5.1.1 LSIS 122 with open cable end ................12 5.1.2 LSIS 122 with serial cable (to 9 pin D-Sub Plug)..........13 5.1.3 LSIS 122 at MA ....................14 5.2 LSIS 123........................15 1.1.1 LSIS 123 with open cable end................15 1.1.2 LSIS 123 with Conncting cable to an USB Type A-Plug .........16...
Seite 3
6.7.6 Rectangular Data Matrix Code................26 6.7.6.1 Activation of Rectangular Data Matrix Codereading........26 6.7.6.2 Disactivation of Rectangular Data Matrix Codereading ........26 6.7.7 Non square Cells in the Data Matrix Code ............27 6.7.7.1 Activation Non square Cells in the Data Matrix Code........27 6.7.7.2 Disactivation Non square Cells in the Data Matrix Code ......27 6.7.8 Cell size in the Data Matrix Code................27 6.7.8.1 Actvation of small Cells in the Data Matrix ...........27...
Both Devices have the same housing and the same M12 8-pin connector, with an Triggerinput and an Switch output. The LSIS 122 have an RS 232-Interface and a 24 VDC voltage supply: The LSIS 123 communicates over the USB-Interface, this interface does also the Voltage...
Seite 5
The parameterisation of the LSIS 120 can be done one 3 different ways: 1. Reading Barcodes with the LSIS 120, for this you must triggering the device with the integrated Triggerbutton or the Switch input on each Barcode/PDF417-Code. 2. Parameterisation with serial Commandos over the RS232-Interface (LSIS122) or the USB-COM-Port-Emulation (LSIS123).
No Read Character: <?> Remark Trigger: SWIN or serial Command 1.Barcode enter/exit 2. Default 3. Configuration LSIS 122 Factory Default 4. Barcode enter/exit The factory parameter are marked later on with this sign. (*). Kurzanleitung LSIS 12x-v171e.doc vom 11/03/2010 Seite 8...
3.2 LSIS 123 3.2.1 Keyboard-Emulation (Factory Default) To read the codes, you must activate the Hardwaretrigger (Switch input or triggerbutton), after the readind the illumination stops automatically. i i i i Data Transmission: USB-Keyboard-Emulation (German Keyboard-Layout) Trigger: Automatically with Presentation Mode Remark i i i i The device use the Standard Windows Keyboard Driver.
3.2.2 COM-Port-Emulation To read the codes, you must activate the Hardwaretrigger (Switch input or triggerbutton), after the reading the illumination stops automatically. Data Transmission: COM-Port-Emulation at Windows PC i i i i Framing protocol: <STX> ..<CR><LF> No Read Character: <?> Remark Trigger: SWIN or serial Command...
Presentationmode (Automatic reading, if something is in the field of view) 4.1 The serial Trigger command With the factory default of the the LSIS 122 or 123 (COM-Port Emulation) you can send the activation with an ASCII-Character. The characters are:...
5.1.2 LSIS 122 with serial cable (to 9 pin D-Sub Plug) Parts: 1. 50110307 LSIS 122 M6M-R1 2. 50111226 KB M12A-8P-PC-IO-3000 option, for powering: 3. 50110650 KD 01-5-BA-PWR The power supply of the BCL 500i Limited Edition can also used !! 4.
5.2 LSIS 123 1.1.1 LSIS 123 with open cable end Parts: 1. 50110306 LSIS 123 M6M-R1 2. 50104591 K-D M12A-8P-2m PUR Colour Signal Trigger Brown SWIN Output Yellow SWOUT Grey Pin 1 white Pin 2 blue Data - Pin 3 pink Data + Pin 4...
1.1.2 LSIS 123 with Conncting cable to an USB Type A-Plug Parts: 1. 50110306 LSIS 123 M6M-R1 2. 50111227 KB M12A-8P-USB-3000 Kurzanleitung LSIS 12x-v171e.doc vom 11/03/2010 Seite 16...
1.1.3 LSIS 123 with Conncting cable to an USB Type A-Plug and IO-M12 socket Parts: 1. 50110306 LSIS 123 M6M-R1 2. 50111228 KB M12A-8P-USB-IO-3000 It is not allowed to power at the M12 connector 5-pin ! i i i i The voltage supply cames every time from the PC.
Code Enter program mode and at the end Exit programm mode. With the factory default of the LSIS 122/123 (COM-Port Emulation) you can setup the device also with ASCII-Strings. You have to use the framing with STX and ETX when you will send...
6.4 Data transmission RS 232 (LSIS 122) Here you can find the Parameter for the serial communication of the LSIS 122. For the Definition of the data transmission over the RS 232-Interface yon need the Parameter: Baudrate, Databit, Stoppbit, Parity and the framing protocol. Please configure the same parameter on the PC/PLC/...
6.4.2 Data-/Stopbits 8 Datenbits 7 Datenbits 1 Stopbit 2 Stopbit 6.4.3 Parity No Parity Even Parity Odd Parity Parity Mark Parity Space Kurzanleitung LSIS 12x-v171e.doc vom 11/03/2010 Seite 20...
6.4.4 Software Handshaking XON/XOFF If you want to use the Software Handshake XON/XOFF, you must aktivate it. XON: [DC3] 19d oder 13h Tastatureingabe: Alt+019 XOFF: [DC1] 17d oder 11h Tastatureingabe: Alt+017 6.4.4.1 Activation of XON/XOFF Sending: [STX]999999[ETX] Recieving: [ACK] Sending: [STX]115914[ETX] Recieving: [ACK] Sending:...
6.4.5 Framing protocol (Prefix/Suffix) With Framing protocol is the discripted the Start and End characters, the characters before the Codeinformation and after Codeinformation. They are also called Prefix or Header for the Startcharacter. For the End character Postfix or Suffix or Terminator. 6.4.5.1 Prefix STX Activation Enable STX...
6.5 Data transmission USB (LSIS 123) Here you can find the Parameter for the serial communication of the LSIS 123. For the Definition of the data transmission over the USB -Interface yon have to activate this and to install an driver on the Windows PC. You can emulate a serial Interface or an Keyboard-Interface.
6.6 Triggermode 6.6.1 Triggermode (Multi-Try Trigger) Enable Multi-Try Triggermode (serial Command: 418324). 6.6.2 Presentationmode Automatic activation of the reading, if something is moving through the field of view.. You must activate for each Configuration-Code the Hardwaretrigger (Switch i i i i Input or Triggerbutton), after the reading of the code the Illumination Lights switch off automatically.
6.7 Data Matrix Code ECC200 6.7.1 Activation Normal Data Matrix Code (black cells on white background) Enable Normal Video Data Matrix (serial Command: 100513). 6.7.2 Activation Inverse Data Matrix Code (white cells on black background) Enable Inverse Video Data Matrix (serial Command: 100512).
6.7.7 Non square Cells in the Data Matrix Code 6.7.7.1 Activation Non square Cells in the Data Matrix Code Enable non-square Data Matrix Codes (serial Command: 125416). 6.7.7.2 Disactivation Non square Cells in the Data Matrix Code Disable non-square Data Matrix Codes (serial Command: 125406).
6.8 QR-Code 6.8.1 Activation Normal QR-Code (black cells on white background) Enable Normal Video QR-Code (serial Command: 200612). 6.8.2 Activation Inverse QR-Code (white cells on black background)) Enable Inverse Video QR-Code (serial Command: 200622). 6.8.3 Activation Normal and Inverser QR-Code black cells on white background and white cells on black background Enable Normal und Inverse Video QR-Code...
6.9 Aztec Code 6.9.1 Activation Normal Aztec-Code (black cells on white background) Enable Normal Video Aztec-Code (serial Command: 100610). 6.9.2 Normal Aztec-Code Deactivation Disable Aztec-Codereading (black on white) Disable Normal Video Aztec-Code(*) (serial Command: 100600). 6.9.3 Activation Inverse Aztec-Code (white cells on black background) Disable Normal Video Aztec-Code(*) (serial Command: 100611).
If the this value is greater-than-or-equal 1 sec, is no serial Data Transmission of Commands to the LSIS 122 possible. This is only working with the value 0. The Parameter 'Sleep Mode timeout' has no influence on the data communiction on the LSIS 123.
6.12 Function Centering Centering window is used to narrow the field of view to make sure the imager reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read. The centering window is specified as a percentage of the whole image.
6. When you start the first time, you have to choice the Interface which you have connected the LSIS 120. With LSIS 122 is this normaly the COM-Port of the PC's. Please take care that you use the COM-Port Emulation at the LSIS 123, and the driver is installed and works, only in this mode you can work with it.
Seite 35
8. To have the datas from the LSIS 120 in the Program MetroSet, click on Upload. The datas will be transmitted 9. Confirm the Upload warning with OK. 10. When the following window appears, all datas are transmitted 11. Click on OK.. 12.
7.2 Function control with the Program MetroSet With the Terminal Window you can check the Data transmission and readability of the Codes. You can trigger the LSIS 120, when you click on the blue Background of the Terminal Window and type Crtl+R. You send than [DC2] and it will shows you in the Terminal Window.