Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA PGS10 Betriebsanleitung Seite 13

Druckmessgeräte mit schaltkontakten
Vorschau ausblenden Andere Handbücher für PGS10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. Commissioning, operation
Requirements for the installation point
If the measuring point is not adequately stable a measuring instrument
support such as a bracket or flange should be used for fastening (and
possibly via a flexible capillary line). If the pressure gauge is exposed to
vibration or pulsating pressure or both, then a liquid filled pressure gauge
may provide considerably better performance and readability. Instruments
should be protected against coarse dirt and wide fluctuations in ambient
temperature.
Installation
Nominal position per EN 837-1 / 9.6.7 Figure 9: 90° ( ⊥ )
Process connection bottom or rear!
In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation!
Measuring assemblies
Proven measuring assemblies for various types of media.
liquid media
Filling of the
liquid
capillary
Examples
condensate
Pressure
gauge above
the tapping
point
Pressure
gauge below
the tapping
point
Admissible ambient and working temperatures
When mounting the pressure gauge it must be ensured that, taking into
consideration the influence of convection and heat radiation, no deviation
above or below the permissible ambient and medium temperatures can
occur. The influence of temperature on the display accuracy must be
observed.
WIKA operating instructions models PGS10, PGS11 and PGS21
liquid with
vapour only gaseous
vapour
"liquefied
boiling liquid
gases"
gaseous media
wet gas
moist air, flue
dry air
gases
GB
liquid gas
condensate
Steam
13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pgs21Pgs11

Inhaltsverzeichnis