S Hardness: at least 40 HRC
The necessary bolts and tightening torques can be found in the table below.
We recommend using a screw locking element to prevent the bolts being acci­
dentally loosened.
Dimension S is used for centering. The centering depth is 1 mm.
Nominal
Thread size
(rated)
for
force
mounting
the U2B
500 N ...
M5
10 kN
20 kN
M10
50 kN
M12
100 kN
M12
200 kN
M16
Installation on the threaded pin of the U2B is described in sections 6.3.1 and
6.3.2.
U2B
Required
Number
bolt
of bolts
strength
8.8
4
8.8
4
8.8
4
8.8
8
8.8
8
A00382_03_YI0_06 HBM: public
Mechanical installation
Mounting base,
customer side
Tightening
D
torque M
A
6 N*m
47
49 N*m
72
85 N*m
86
85 N*m
122 105 16
210 N*m
142 125 26
∅G
∅S
J
42
13
34
70
20.5 55
78
19
61
79
97
21

Quicklinks ausblenden: