Faults & Troubleshooting
DANGER - Risk of electric shock from live
parts!
Work on electrical systems or equipment
must only be performed by qualified
electricians or trained personnel under
the guidance and supervision of an
electrician.
Observe the electrical engineering safety
regulations.
5.1

General view of all faults

Symptom / fault message
Nothing displayed after being switched on
"No battery connected"
"Warning! Checking clips"
"Warning! Overvoltage"
"Fault! Call customer service"
"Fault no.: 10"
"Fault no.: 20"
"Fault no.: 30"
"Fault no.: 40"
"Fault no.: 100"
"Fault no.: 110"
"Fault no.: 120"
"Fault no.: 130"
"Fault no.: 140"
"Fault no.: 200"
"Fault no.: 210"
"Fault no.: 220"
"Fault no.: 230"
"Fault no.: 290"
"Fault no.: 300"
"Fault no.: 310"
"Fault no.: 320"
"Fault no.: 330"
"Fault no.: 340"
"Fault no.: 350"
"Fault no.: 360"
"Fault no.: 370"
"Fault no.: 390"
Robert Bosch GmbH
Faults & Troubleshooting | BAT 690 | 27
5.2

Faults in initialization mode

Nothing displayed after being switched on
Possible cause:
R
Power supply cable with open circuit
R
Connection between circuit board M1 and power
module is interrupted
R
Device fuse is defective
R
Auxiliary voltage is defective
R
Circuit board M1 is defective
Remedy:
1. Check the power supply unit for continuity.
2. Replace the power supply cable if there is a
malfunction.
Remedy
DANGER – Risk of electric shock from live
on page
parts. Observe the electrical engineering safety
27
regulations.
28
3. Establish and secure connection between circuit
board M1 and power module 1 (see sec. 6).
28
4. Check mains voltage at power module 1 and power
28
module 2 at measuring points M1 and M2 (see sec.
28
5.6).
28
 Mains voltage must be 230 V.
28
 Device fuse is defective if mains voltage differs.
29
5. Replace corresponding power module if mains
29
voltage differs.
6. Check auxiliary voltage at power module 1 and
29
power module 2 at measuring points IC 14 Pin 1 and
29
GND1 Pin 4 (see sec. 5.6).
29
 Auxiliary voltage must be 12 V.
29
7. Replace corresponding power module if auxiliary
29
voltage differs.
30
8. Connect customer service circuit board M1 to power
30
module 1 and BAT 690 check function.
 If BAT 690 functions with the customer service
30
circuit board M1, the M1 circuit board of the cus-
30
tomer is defective.
30
9. Replace the customer's M1 circuit board.
31
10. Define power module 1 with jumper setting as Slave
31
1 (see sec. 4.4.4).
31
11. Connect power module 2 to circuit board M1 and
31
BAT 690 check function.
 If BAT 690 functions, power module 1 is defec-
32
tive.
32
 If BAT 690 does not function, power module 1
32
and power module 2 are defective.
32
12. Replace power module 1 and/or power module 2.
33
en
|
1 689 975 288
2017-06-30