Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance; Wiring Instructions - JABSCO 50830 Bedienungsanleitung

Niederdruckumwälzpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6

Operation

Pump may be run dry for short periods of time.
Pump may be run against a closed discharge.
WARNING: Motor may get hot after
prolonged use, do not touch. Burns
may occur.

Maintenance

Check all electrical connections periodically.
Check seal area for signs of leaking.

Wiring Instructions

Make all electrical connections in dry locations.
In humid/wet environments, connections must be sealed to
prevent corrosion.
Protect the circuit with a correctly fitted fuse or circuit
breaker in the red/orange positive (+ve) lead, as close as
possible to the power source.
Connect the black negative (-ve) lead to the negative
battery terminal.
Inadequate voltage at the pump (not more than 3% below
rated voltage) may result in blowing fuses, poor pump
performance, or failure for the pump to start. See table for
wire sizing.
Overload
Protected
Distribution
Panel
Electrical Wiring Information
Model No
Voltage
50830-XX12
12v
50830-XX24
24v
*wire length from battery to pump and back to battery, maximum voltage drop 3%
WARNING: If the fuse fails repeatedly,
do not fit a heavier fuse or bridge the
terminals. Fire and death may occur.
Dis-Assembly
1. Disconnect pump from power supply. Remove 3 end cover
bolts, end cover & o-ring.
2. Carefully holding impeller, remove impeller nut.
3. Remove impeller.
4. Loosen 2 head fixing bolts, rotate pump head and pull
to remove.
5. Remove seals from pump body.
Re-Assembly
6. Wet the flat seal part and cup rubber and push into head.
7. Fit head to motor locking into position and tighten head
fixing bolts.
8. Lubricate inside of mechanical seal and push onto shaft.
9. Fit and carefully hold impeller and tighten nyloc nut. Once
tight, carefully hold impeller and undo nut 1 revolution to
set impeller clearance.
10. Fit o-ring to end cover and fit onto head.
11. Tighten 3 end cover bolts.
ORANGE
WIRE
BLACK
WIRE
BATTERY
INLET
PORT
Max
Max
Amp
Fuse
Draw
Size
9.0A
10A
4.5A
7A
(See diagrams on inside back cover)
(See diagrams on inside back cover)
Wiring Diagram
FUSE
OUTLET
PORT
Wiring size*
2
AWG
mm
14
2.5
4.5m (15ft)
10
6.0
9.0m (30ft)
18
1.0
4.5m (15ft)
16
1.5
9.0m (30ft)
Max.
Length

Werbung