Winterizing
CAUTION: Allowing water to freeze in the system may result in damage to the
pump and plumbing system. Non-Toxic antifreeze for potable water may be
used with Jabsco pumps. Follow manufacturer's recommendations. Refer to
boat or equipment manufacturer's instructions for their specific winterizing and
drainage procedures. Do not use automotive antifreeze to winterize potable
water systems . These solutions are highly toxic and may cause serious injury
or death if ingested.
1. Drain the water tank. Open tank drain valve. You may use the pump to drain
the tank by opening all the faucets in the system. Allow the pump to operate
until the tank is empty. Do not operate the pump more than 15 minutes
continuously.
2. Open all faucets and purge the water from the plumbing system. Turn off
power to the pump. Be sure that all the water from the drain lines is drained.
3. Remove quick-connect inlet and outlet fittings from the pump and turn the
pump on to pump out remaining water from the pump head. Be sure to
have a catch pan or a rag under the pump to prevent water from spilling
onto the boat. Turn the pump off once the plumbing is empty. Leave the
fittings disconnected from the pump until the system is ready to be used
again. Make a note on your tank filler that the plumbing is not connected.
4. Be sure that all faucets are left open to protect against damage to the
plumbing.
Model Reference
Model
Nominal DC Volts
42755-0092
42755-0094
42755-0392
42755-0394
Dimensions:

Operation

Attribute
Time to reach full speed after faucet opened
Time to shut off after faucet completely closed
Over Voltage Threshold Setting (Unit automatically shuts off / will not run)
Under Voltage Threshold Setting (Unit automatically shuts off / will not run)
Under Current Threshold Setting (Unit automatically shuts off / will not run)
KEY
2
Valve Kit
3
Diaphragm Kit
4
Lower Housing Kit
5
Pressure Switch
6
Service Kit
Motor 12V DC
7
Motor 24V DC
8
Side Clips
9
Pump Head Assembly
10
Pumpgard™ Strainer (not shown)
Accessories – Snap-In Port Fittings
30649-1000
QUAD PORT x 1/2"
MALE QEST. STRAIGHT
30655-1000
QUAD PORT x
1/2" MALE QEST.
90º ELBOW
We hereby declare, under our sole responsibility, that our product
to which this declaration relates has been designed to comply in
accordance with the following Directives:
Electromagnetic Compatibility Directive 2004/108/EC
Recreational Craft Directive 2003/44/EC
Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU
With the relevant selections of the following Standards:
ISO 8846:1990 / Ignition Protection
6
Open Flow
GPM (LPM)
12V dc
5.0 (19)
24V dc
5.0 (19)
12V dc
5.0 (19)
24V dc
5.0 (19)
Width – 6 1/8 inches (155.58mm), Height – 4 3/4 inches (120.65mm),
Length – 9 7/8 inches (250.83mm)
Description
30654-1000
QUAD PORT x 1/2"
HOSE BARB STRAIGHT
Operating Pressure
PSI (Bar)
40 (2.75)
40 (2.75)
25 (1.72)
25 (1.72)
Model No.
18911-7030
18912-3040
18915-9002
37121-0010
18920-9043
18753-5236
18753-5237
30648-1000
18914-0030
46400-9500
30653-1000
QUAD PORT x 3/4"
HOSE BARB STRAIGHT
30651-1000
QUAD PORT x
1/2" HOSE BARB
90º ELBOW
Install to ABYC
H-22, H-23 and E-11
Cut-out
Pressure PSI (BAR)
60 (4.1)
60 (4.1)
35 (2.4)
35 (2.4)
12 Volt
24 Volt
5 seconds
5 seconds
or less
or less
5 seconds
5 seconds
or less
or less
16 Volts DC
31 Volts DC
9 Volts DC
18 Volts DC
2 AMPS
2 AMPS
QTY
1
1
1
1
1
1
1
1
1
1
30650-1000
QUAD PORT x
GARDEN HOSE STRAIGHT
30642-1000
QUAD PORT x
3/4" HOSE BARB
90º ELBOW

Werbung

loading

Diese Anleitung auch für:

42755-009442755-039242755-0394