holding down the button (17), the synchro function is
activated/deactivated. When pressing the travel but-
ton (6-7), the control systems synchronise and then
move in the confirmed direction of travel. After suc-
cessful activation, the button glows blue continuous-
ly. After successful deactivation, the button appears
white.
Under-floor lighting
Activate the under-floor lighting by pushing the „Un-
der-floor lighting" button (8). This switches off auto-
matically after 30 minutes, or if the button is pushed
once again. This button is illuminated (blue) when it
is pushed.
Pocket lamp
The pocket lamp is illuminated when the „Pocket
lamp" button (5) is held down. The light turns off
when the button is released. This button is illumina-
ted (blue) while the pocket lamp is in use.
Lock buttons
To lock the buttons, hold down the „Lock buttons"
button (20) for five seconds. Once the button lock has
been activated, all buttons (except for the mains out-
let (19), the pocket lamp (5), the under-floor lighting
(8) and the button lock (20)) flash (blue) twice.
All buttons flash twice (white) when a disabled button
is pushed. The lock is disabled by holding down the
„Lock buttons" button (20) for five seconds. All but-
tons flash twice (blue) if this was successful.
Adjustment options
The sleep and sit positions have been pre-program-
med in the factory.
M1
Read and watch TV without getting tired
M2
Relieving position for colds, respiratory disor-
ders or cardiovascular complaints
M3
Ergonomic position for backaches and inver-
tebral disk complaints
M4
Aids for getting into and out of the bed
The positions can be overwritten individually.
Resetting the factory-programmed memory posi-
tions
Hold down the memory button (18) for 3 seconds –
the background lighting then flashes once, the under-
floor lighting button (8) must then be pressed within
a second. The entire RF-Touch lighting flashes twice
to confirm that the factory settings have been reset.
Saving the sitting and lying position to a memory
button
1. Press the memory button (18) 3x within 2 seconds.
2. The memory button is illuminated (blue) (1–4).
14
Operating instructions
3. Press the desired memory button for memory po-
sition 1–4 (1–4) 1x within three seconds.
The programming of a new position automatically
overwrites an old position. A successful save is visu-
alised by a change in colour of the selected memory
button LED (white). All memory buttons turn white
two seconds after the memory button is released.
To call up a position stored in memory
Press the desired memory button for memory po-
sition 1–4 (1–4), until all the comfort sections have
reached the programmed position. The activated
memory button is illuminated (blue) during the travel
time.
To reset to the horizontal position
Press the "all motors down" button (7) to simultane-
ously move all sections to the horizontal position.

Care and Maintenance

Your uni 20_/22_95RF bridge
duct that has been designed to serve you reliably for
many years to come. For occasional cleaning and
the removal of dust, we recommend the use of a dry
cloth.
Changing the batteries in the radio remote control
Remove the cover from the battery compartment (21)
on the back of the radio remote control. Place three
AAA batteries into the compartment, paying attention
to the +/- markings. Close the compartment cover
again.
Changing the batteries (22) in the uni 20_/22_95RF
bridge
switching power supply (batteries for emer-
®
gency lowering)
Carefully remove the batteries from the battery
clips. Place two 9V block batteries in the compart-
ment, paying attention to the +/- markings. The bat-
teries in the switching power supply provide power
in the case of a power failure.

Troubleshooting

In case of malfunctions with your uni 20_/22_95RF
bridge
, consult the following troubleshooting tips. If
®
the problem cannot be resolved, disconnect the uni
20_/22_95RF bridge
®
tact your Swissflex stockist.
Loss of power in the sitting position
In case of a power failure, a battery pack (2 x 9V) is
located in the switching power supply connected to
the motor control, which allows you to move the bed
to the flat sleeping position (30). Use the "all motors