Troubleshooting
Fault
Start attempt with
≥ U
U
TERM
ON
Electric circuit between
the pins in the compres-
sor interrupted
U
Voltage between the positive and negative terminals of the electronics
TERM
U
Cut-in voltage of the electronics
ON
U
Cut-off voltage of the electronics
OFF
Poor cooling, interior temperature increases
Fault
Compressor runs for a
long time/continuously
Compressor runs
intermittently
18
Possible cause
Ambient temperature too high
Insufficient ventilation and/or air
supply
Condenser is dirty
Fan defective (if installed)
Defective compressor
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
MR07, MRR07, MH07
Remedy
Move the refrigerator to
another location
Clean the condenser
Replace the fan
This can only be repaired
by an authorised
customer services unit.
Remedy
Defrost the vaporiser
Move the refrigerator to
another location
Clean the condenser
Replace the fan
Charge the battery