Herunterladen Inhalt Inhalt Diese Seite drucken

Appendix; Technical Data; B Technical Data - Vaillant ecoTEC pure series Umrüstanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

Appendix

A

Technical data

Applicability: Except Germany
Gas adjustment values as set at the fact-
ory
CO₂ after 5 minutes in full load mode with
front casing installed
CO₂ after 5 minutes in full load mode with
front casing removed
O₂ after 5 minutes in full load mode with front
casing installed
B
Technical data
Applicability: Germany
Gas adjustment values as set at the fact-
ory
CO₂ after 5 minutes in full load mode with
front casing installed
CO₂ after 5 minutes in full load mode with
front casing removed
O₂ after 5 minutes in full load mode with front
casing installed
0020241514_03 Conversion instructions
Unit
G20 natural
G25 natural
gas
9.2 ± 0.3
9.0 ± 0.3
Vol.–%
9.0 ± 0.3
8.8 ± 0.3
Vol.–%
4.5 ± 0.5
4.6 ± 0.5
Vol.–%
Unit
G20 natural
G25 natural
gas
9.4 ± 0.3
9.0 ± 0.3
Vol.–%
9.2 ± 0.3
8.8 ± 0.3
Vol.–%
4.2 ± 0.5
5.0 ± 0.4
Vol.–%
G25.3
gas
natural gas
natural gas
9.0 ± 0.3
10.3 ± 0.3
8.8 ± 0.3
10.1 ± 0.3
4.6 ± 0.5
5.0 ± 0.4
G31
gas
propane
10.4 ± 0.3
10.2 ± 0.3
5.1 ± 0.4
Appendix
G230
G31
propane
10.4 ± 0.3
10.2 ± 0.3
5.1 ± 0.4
21

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis