If you press the button for a longer time, the lowering ramp
for the current starts, thus reaching the final current.
By releasing the button again, the arc goes out and the
gas continues to flow for the post-gas stage.
Parameter setting: Amperes (A) - Percentage (%).
Minimum 5A-1%, Maximum Imax-500%, Default 50%
10
Basic current
Permits adjustment of the basic current in pulsed and
fast pulse modes.
Parameter set in Amps (A).
Minimum 5A-1%, Maximum Weld current-100%,
Default 50%
12
Pulsed frequency
Allows activation of the pulse mode.
Allows regulation of the pulse frequency.
Allows better results to be obtained in the welding of
thin materials and better aesthetic quality of the bead.
Parameter setting: Hertz (Hz) - KiloHertz (kHz).
Minimum 0.1Hz, Maximum 250Hz, Default off
13
Pulsed duty cycle
Allows regulation of the duty cycle in pulse welding.
Allows the peak current to be maintained for a shorter
or longer time.
Parameter setting: percentage (%).
Minimum 1%, Maximum 99%, Default 50%
Peak time
Permits adjustment of the peak time during pulse and
fast pulse operation.
Parameter setting: seconds (s).
Minimum 0.02s, Maximum 2.00s, Default 0.24s
Background time
Permits adjustment of the background current time dur-
ing pulse and fast pulse operation.
Parameter setting: seconds (s).
Minimum 0.02s, Maximum 2.00s, Default 0.24s
14
Fast Pulse frequency
Allows regulation of the pulse frequency.
Allows focusing action and better stability of the electric
arc to be obtained.
Parameter setting: KiloHertz (kHz).
Minimum 0.02KHz, Maximum 2.5KHz, Default off
15
Pulsed slopes
Allows setting of a slope time during the pulse operation.
Allows a smooth step to be obtained between the peak
current and the basic current, having a more or less soft
welding arc.
Parameter setting: percentage (%).
Minimum off, Maximum 100%, Default off
16
Slope-down
Allows you to set a gradual passage between the weld-
ing current and the final current.
Parameter set in seconds (s).
Minimum off, Maximum 99.9s, Default off
17
Final current
Permits adjustment of the final current.
Parameter set in Amps (A).
Minimum 5A-1%, Maximum Imax-500%, Default 10A
19
Final current time
Makes it possible to set the time for which the final cur-
rent is maintained.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
20
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum 0.0s, Maximum 99.9s, Default syn
204
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
205
Restart
Allows the activation of the restart function.
Allows the immediate extinguishing of the arc during
the down slope or the restarting of the welding cycle.
0=Off, 1=On, Default On
206
(TIG DC) Easy joining
Allows striking of the arc in pulsed current and timing
of the function before the automatic reinstatement of
the pre-set welding conditions.
Allows greater speed and accuracy during tack welding
operations on the parts.
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 25.0s, Default off
208
Microtime spot welding
Allows you to enable the "microtime spot welding"
process.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum 0.01s, Maximum 1.00s, Default off
500
Allows access to the higher set-up levels:
SERV: service
vaBW:vaBW
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
552
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
751
Current reading
Allow the real value of the welding current to be dis-
played.
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
853
TIG Lift Start
On TIG Lift Start (with torch button)
Off TIG Lift Start (without torch button)
List of set up parameters (MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the manual MIG (
gic MIG (
) process by setting the type of mate-
rial to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 16 m/min, Default 1.0m/
min
4
Current
Allows the regulation of the welding current.
Minimum 5A, Maximum Imax
) or syner-
43

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading