Herunterladen Inhalt Inhalt Diese Seite drucken

Gas Connection - Bartscher MFGO 7060 / 1582101 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für MFGO 7060 / 1582101:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Before connecting the device make sure that the voltage and frequency values on
the rating plate are consistent with the existing electric installation.
The allowable voltage deviation is ±10%.
Connect the device to the electric installation according to the valid international,
national, and local regulations.
The device is equipped with the electric cable of type H07RN-F 5G2.5 CE14 without
the plug.
The device must be connected to the potential levelling circuit (ground).
The connection terminal is located under the left side of the device at sign

5.1.3 Gas connection

WARNING!
The device installation and any adaptation to different gas type must be
performed only according to the valid regulations and by the qualified
professional personnel.
The device should be inspected by the professional personnel at least
once a year. In case of fire immediately close the gas valve and use the
appropriate fire extinguisher!
The device is designed and certified for operation with the gas type specified on the
rating plate. Before the installation make sure that the local gas supply system (gas
type and pressure) conforms to the device preset.
The gas connection is located on the left side of the device and is marked "GAS".
The device must be connected to the gas system only by the qualified gas installer
according to the local regulations.
In generally accessible installation locations follow the safety regulations, as well as fire
and panic protection standards.
The certified gas valve must be located in easily accessible place between the gas
system and the device allowing for quick gas supply cutting off.
Make sure that the gas hose does not touch hot oven parts.
- 46 -
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis