LC-A
- ELECTRONIC BOARD
AND CONNECTIONS
SEA
L N N
L N
230V ~
LEGEND:
DIP
=
IN2
IN1
=
FUNCTION OF THE AUXILIARY CONTACTS
• Contact IN1 : Remote ON-OFF (see DIP 3 setting).
- with DIP No 3 set on ON
• contact closed = ON fan
• contact open = OFF fan
• Contact IN2 (DSC): - Dorr Contact -
When the contact is open the appliance can operate.
When the contact is closed the appliance is stopped.
- DIPSWITCHES SETTINGS
Connecting auxiliary contacts IN1 / IN2
SETTING TIME POST-VENTILA-
DIP No 1 and DIP No 2 -
TION (Function is associated with DSC - door contact)
0 sec.
DIP
DEFAULT
1
OFF
OFF
2
OFF
OFF
ON
DIP
DEFAULT
CONTACT IN1 (remote On/Off)
3
OFF
ENABLED
Button P1
Button P1
4
4
OFF
OFF
DISABLED
DISABLED
Dip dedicated to manufacturer
IN2
(DSC)
IN1
RL1
RL2
30 sec. 60 sec. 90 sec.
POSITION
ON
ON
OFF
ON
ON
OFF
POSITION
OFF
CONTACT IN1 (remote On/Off)
DISABLED
Button P1
Button P1
ENABLED
ENABLED
- USING THE CONTROL
DL3
DL2
P1 = On / Stand By / Set the fan speed
DL1 = On / Stand By led
DL2 = Low speed led
DL3 = High speed led
• At Power On the control takes the stored state at the
time of power failure.
press the P1 button to select the stand-by mode.
In stand-by mode DL1 is turned on, while DL2 and DL3 off.
• Press the P1 button to set low speed: DL1 and DL2 are
on while DL3 off.
• Press again the P1 button to set high speed: DL1 and
DL3 are turned on, while DL2 off.
P1
Stand-by
P1
NOTE!:
DIPSWITCHES SETTINGS)
DL1
P1
Low
Speed
P1
High
Speed
Low
Speed
P1
English
39

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis