Warning! Outdoor air temperature sensor failure.
.
Emergency run
Warning! Hydronic heater water temperature sen-
.2
sor failure. Emergency run
Warning! Hydronic pre-heater water temperature
.2
sensor failure. Emergency run
Warning! Hydronic cooler water temperature sensor
.22
failure. Emergency run
Warning! Controller cabinet temperature sensor
.23
failure. Emergency run
Alarm! Supply air temperature sensor failure.
A.2
System stopped
Alarm! Extract air temperature sensor failure.
A.25
System stopped
Alarm! Exhaust air temperature sensor failure.
A.26
System stopped
Alarm! Outdoor air temperature sensor failure.
A.27
System stopped
Alarm! Hydronic heater water temperature sensor
A.2
failure. System stopped
Alarm! Hydronic pre-heater water temperature sen-
A.2
sor failure. System stopped
Alarm! Hydronic cooler water temperature sensor
A.3
failure. System stopped

7.4.26. EVENT LOG (HISTORY)

The system records 50 recent events (failures, alarms, fire damper testing results, etc.).
The log stores the description of events and time.
The event log may be reviewed in the window ADJUSTER › HISTORY or USER › MENU › HISTORY.

7.4.27. SYSTEM VERSIONS AND RUNNING TIME

In the section ADJUSTER › USER SETTINGS › ABOUT you may see software and configuration versions that are saved in the production line namely to every unit.
Next to them the running time since the unit has been manufactured is also displayed. It is calculated when the fans are rotating.

8. ACCESSORIES

Filters
Filters
panel
pocket
MB Gate-
CM24-F-L
way
PA-
AL
TROL_701
26
| DE
Heater
Damper
Cooker
electrical
circular
circular
S-KCO2
S-KFF-U
S-RFF-U-
Warning! Too high 3 days extract humidity. Increas-
.
ing air flow.
Warning! Too high extract humidity. Boosting.
.5
Alarm! Rotor broken belt alarm. System stopped.
A.5
Warning! Gas heater failure
.52
Warning! Gas pre-heater failure
.53
Warning! Too high condensation level
.5
Warning! Supply fan failure. Emergency run
.55
Warning! Extract fan failure. Emergency run
.56
Warning! Too low supply air flow for DX cooler
.57
Alarm! Bypass damper failure. System stop-
A.5
ped.
Alarm! Hydronic heater/pre-heater circ.
A.5
pump failute. System stopped.
Warning! Hydronic heater/pre-heater circ.
W.6
pump failute.
Silencer
Front
hood
circular
cover
S-RCO2-F2
Coupling
D-F2
without
sealing
Bracket
Stouch
SA-Control
Clamp
TL-
WR802N
SMARTY RV v2019.04
IR24