1. TECHNICAL DATA

As a stove of construction type 1, it is possible to
connect it to the chimney together with an exisiting
other stove or another hearth for solid fuels, as long
as the chimney caleutation complies with DIN 4705,
Part 3. See page 6 for information concerning
operation with external air supply.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
2. IMPORTANT INFORMATION
The installation and operation information given here
. National and European
is of general nature
standards, local and building regulations as well as
fire prevention laws must be observed during the
operation of the stove.
General safety instructions for
the operation of your stove
Thoroughly read the entire manual before
starting up your stove and observe the caution
notices.
Your heating unit must not be moved without
approved means of transport with sufficient load-
bearing capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
Please keep in mind that
your stove's surface heats up
considerably during operation.
We
therefore
recommend
wearing a safety mitten when
operating your stove.
Make your children aware of this particular
danger and keep them at a distance from the heating
unit whenever it is in operation.
Only burn approved fuels and materials listed in
the chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans, etc. into the
firebox as well as the storage of such materials in the
immediate vicinity of your heating unit is strictly
forbidden due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
5
Smallest heating capacity
Room heating capacity (depending on
building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
932 mm
Fluegas mass flow
460 mm
460 mm
Fluegas temperature
150 kg
Minimum feed pressure
130 mm
Nominal thermal output
6 kW
8 kW
Placing
heating unit or in the vicinity of the heating unit is
forbidden.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of fire.
The woodstove LUCY COOK is not suitable for
long term heating.
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located.
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2)
A > 800 mm
B > 100 mm
C > 100 mm **
(A – toward the front in the radiated area)
(B – to the side)
(C – to the back)
** = 200 mm if flue connection pipe is not
isulated
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
room as the stove
closed
closed
closed
at 0.8 times
n. ther. outp.
non-heat-resistant
objects
.
Lucy Cook
3,5 kW
65 – 165
4,9 g/s
290 °C
12 Pa
9,6 Pa
on
the
(Minimum