If the node is connected to a network with firewall, in order to allow Unicast Link connections, TCP and UDP ports
listed on the WEB page need to be configured. The following ports are used:
TCP/554 RFC 2326 Real Time Streaming Protocol (RTSP)
UDP/7000 Livewire synchronization protocol
UDP/16384 Audio RTP stream to destination #1
UDP/16386 Audio RTP stream to destination #2
UDP/16388 Audio RTP stream to destination #3
UDP/16390 Audio RTP stream to destination #4
The basic setup establishes four bidirectional streams. If the needs are for less audio links, bandwidth utilization can
be reduced if the settings are customized. This is done by disabling unused channels through the Source page. The
setup wizard mention above would have set all source streams to standard stereo.
In Unicast Mode, the front panel presents the link status information as triangles below the meters.
If no triangle is shown, the Source and Destination port is not configured for Unicast.
If the triangle is blinking, the port is configured for Unicast, but there is no active connection.
When the triangle is displayed solid on, there is a Unicast Link established to that port.
Figure 3-17