Quick Start Guide
AP10T
Setpoint display
For detailed documentation please refer under
http://www.siko-global.com/p/ap10t
General information
Prior to installation, including in hazard areas, read the Installation Instruc-
tions (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
• Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
• It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation Instructions.
• It is the responsibility of the customer to ensure that the setpoint display is
correctly connected and configured.
• Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
SIKO GmbH
Weihermattenweg 2
Phone: + 49 7661 394-0
79256 Buchenbach
Fax: + 49 7661 394-388
www.siko-global.com
Service: support@siko.de
AP10T · Date 22.04.2015 · Art. No. 88404 · Mod. status 146/15
Mechanical mounting
Fasten the device via the threaded holes on the rear on a level support .

Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the setpoint display or the connection lines!
• All lines for connecting the setpoint display must be shielded. Strand cross
sections of lines ≥0.14 ... ≤0.5 mm².
• Do not disconnect or close live connections.
• Perform wiring work in the de-energized state only.
• Use strands with suitable ferrules.
• Prior to switching on check all mains and plug connections.
• The running of wiring parallel to the mains supply should be avoided. Use
screening shields or metallized housings.
• Contactor coils must be linked with spark suppression.
Pin assignment
PIN
Designation
1
DÜB/CANL
2
DÜA/CANH
3
+UB
4
GND/SGND
Commissioning
The setpoint display features a two-row display, three operating keys, an
acknowledgment key and an LED display with two LEDs.
In the basic state, setpoint 1 is displayed in the upper row and setpoint 2 is dis-
played in the lower row.
Configuration
• Pressing the
key starts the parameter / programming mode.
The required parameters are set in the configuration mode. On the 1st line of
the display, the parameter will be shown and on the 2nd line the respective
value will be displayed.
Press
key for changing actual value and / or the blinking digit when enter-
ing a multi-digit value.
The
key serves for switching to the next digit in case of multi-digit numbers.
By pressing the
tilely. If no key is pressed, the configuration mode will be exited after ~30 s
without saving the latest value displayed, i. e. the original value will be main-
tained.
Configuration parameters CAN
Parameter
Value range
ID
1 ... 127
dim. ød
2x M5, 7 mm deep
dim. L1
22
dim. L2
20 ±0.15
KBAUD
125, 250, 500, 800,
1000kbd, Auto
Configuration parameters RS485
Parameter
Value range
ID
1 ... 127
KBAUD
19.2, 57.6, 115.2
Additional configuration parameters can be found in the detailed documenta-
tion.
Technical data
Electrical data
Operating voltage
Current consumption ~30 mA
Bus IN
Bus OUT
viewing side = plug-in side
key, the set value is acknowledged and saved non-vola-
Default
Meaning/Remark
125
bus address
NOTICE
Restart is required after changing
these parameters!
Auto
CAN baud rate (e. g. 250 kbit/s)
Default
Meaning/Remark
31
bus address
NOTICE
Restart is required after changing
these parameters!
57.6
SIKONETZ baud rate (e. g. 57.6 kbit/s)
Additional information
24 V DC ±20 %
if operated with LEDs, additional ~3 mA