Herunterladen Diese Seite drucken

Siemens RDG160KN Installationsanweisung Seite 2

Vorschau ausblenden Andere Handbücher für RDG160KN:

Werbung

S1
S2
B1
B2
QAH 11.1
QAH11.1+
QAA 34
A RG86.3
X1
M X2
D1 GND
max 5(4)A
G
G0
L
Q1 Q2 Q3
10 A
L
AC 230 V
N
G0
10 A
G
Outputs
V1
L3
2-pipe
φ
h/c
S1
B1
QAH11.1
QAA34
X1
M X2
G
G0
10 A
L
AC 230 V
N
G0
10 A
G
Outputs
V1
V2
2-pipe
&
E
h/c
el. heater
h/c
2-pipe
& radiator
RAD
V
V
4-pipe
2-stage
st
nd
1
2
P01=0
P01
P02
P01=1
P12
Pn
P01=2
2-Rohr Ventilator-
2-pipe fan coil
konvektor
2-Rohranwendung &
2-pipe & el. heater
Elektroheizung
2-Rohranwendung &
2-pipe & radiator
Radiator
4-Rohr Ventilator-
4-pipe fan coil
konvektor
2-stage
2-Stufen-Anwendung
ã 2012 -2015 Siemens Switzerland Ltd.
2 / 2
2015-01-20
KNX
S3
L
10 A
CE+ CE-
max . ± 1 mA
Q1 Q2 Q3
L
Y50
Y10
Y20
L1
L3
M1
V1
φ
N
V1
N
DC DC
On/Off
Y10
Q1
Q3
ON
ON
OFF
OFF
1
2
3
4
5
1
2
S2
KNX
S3
B2
QAH11.1+
ARG86.3
D1 GND
CE+ CE-
max. ± 1 mA
L
Q1 Q2 Q3
Y50
Y10
Y20
L3
M1
V1
V2
φ
DC DC DC
On/Off On/Off DC
Y10
Y20
L3
Q3
ON
ON
φ
OFF
OFF
1
2
3
4
5
ON
ON
φ
OFF
OFF
1
2
3
4
5
ON
ON
φ
OFF
OFF
1
2
3
4
5
ON
ON
φ
OFF
OFF
1
2
3
4
5
X2
M
P01=3
X2
M
AU TO
P01=4
P3191
Ventiloconvecteur
2 tubes
Application 2 tubes &
batterie électrique
Application 2 tubes &
radiateur
Ventiloconvecteur
4 tubes
Application à 2 étages
M3191.1
AC 230 V
L
10 A
max 5(4)A
max . ± 1 mA
Y50
Y10
Y20
L
L3
M1
φ
G0
N
G
DC
3-speed
Y50 + [DC è On/Off]
Q3
ON
P46=1
(On/Off)
OFF
3
4
5
1
2
L
AC 230 V
10 A
max . ± 1 mA
L
Q1 Q2 Q3
Y50
Y10
Y20
L1
L2
L3
M1
φ
N
G0
V1
V2
G
N
Q1
Q2
Q3
ON
P46=1
P47=1
OFF
1
2
3
4
5
ON
P46=1
P47=1
OFF
1
2
3
4
5
ON
P46=1
P47=1
OFF
1
2
3
4
5
1
ON
P46=1
P47=1
OFF
1
2
3
4
5
L
AC 230 V
10 A
max. 1 A
L
Q1
Q2 Q3
L1
L2
L3
N
L1: f(Q1) à P72 (RDG165KN)
L2: f(Q2) à P73 (RDG165KN)
L3: f(Q3) à P74 (RDG16..)
P3191
Fan coil 2 tubi
Fancoil a dos tubos
Fan coil 2 tubi con
2 tubos & batería
batteria elettrica
eléctrica
Fan coil 2 tubi e
2 tubos & radiador
radiatore
Fan coil 4 tubi
Fancoil a 4 tubos
2 stadi
2 etapas
1)
AC 230 V
2)
max . ± 1 mA
max 5( 4) A
Y50
Y10
Y20
Q1 Q2 Q3
DC
C1
V1
I
II
III
On
Off
ON
φ
L3
M1
3)
OFF
1
G0
G
4)
DC
Y10
5) G, G0 AC 24 V à P01...Pn
P46 = 1 à V1 On/Off
P46 = 2 à V1 DC
P47 = 1 à V2 On/Off
P47 = 2 à V2 DC
3
4
5
L
AC 230 V
10 A
max . ± 1 mA
max 5( 4)A
Q1 Q2 Q3
Y50
Y10
Y20
L
L2
L3
M1
V1
φ
N
G0
G
On/Off
DC DC
Y10
Q2
Q3
P46=2
P47=1
1
2
3
4
5
P46=2
P47=1
1
2
3
4
5
P46=2
P47=1
2
3
4
5
P46=2
P47=1
1
2
3
4
5
KNX programming mode
ON
min. 6 s
ACS
KNX Bus
Tool
2-pijps fan coil
2-pijps +
elektrische verwarmer
2-pijps + radiator
4-pijps fan coil
2-traps
...
5
Output à AC 230 V, On/Off
or DC 0...10 V
2
3
4
5
L
AC 230 V
10 A
max 5(4)A
max. ± 1 mA
L
Q1 Q2 Q3
Y50
Y10
Y20
DC
V2..
C1
V1
I
II III
On
Off
φ
M1
L3
N
G0
G
3-speed
DC DC
Y10
Y20
Y50 + [DC è On/Off]
ON
OFF
1
2
3
4
5
ON
OFF
1
2
3
4
5
ON
OFF
1
2
3
4
5
ON
OFF
1
2
3
4
5
P01...Pn
1)
www.siemens.com/HIT
(HIT start center)
2)
"RDG"

3)
(doc)
2 borulu fan coil
2 borulu & elk. Isıtıcı
2 borulu & radyatör
4 borulu fan coil
2 kademe
Siemens Building Technologies

Werbung

loading

Diese Anleitung auch für:

Rdg165kn