Herunterladen Inhalt Inhalt Diese Seite drucken

Leister WELDPLAST S6 Bedienungsanleitung Seite 30

Hand-extruder
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operation
Programming the welding parameters
Menu
Select program
Selection
Enter
The handheld extrusion welder is suitable for the following types of thermoplastic materials:
• PP/PE-HD/PE-LD
Programs 1 – 3 are preset with suitable values which can be adapted during the welding process.
The adjustments are not saved!
The free settings 1 – 4 are preset at the factory and can be programmed freely. The parameters will be stored even
after the device has been switched off.
Welding program
Free set. 1 – 4
Prg1 PE-LD
Prg2 PE-HD
Prg3 PP
The currently set welding program (17) is shown in the working display.
Setting the output volume
• Press the Select key (28) to move the cursor to the "SPEED" position.
• Set the output value (60 to 100) with the Up key (29) or the Down key (27).
Setting the PLAST and AIR temperatures
• Press the Select key (28) to move the cursor to the "PLAST" or "AIR" position.
• Set the temperature value with the Up key (29) or the Down key (27).
30
Setpoint PLAST [°C]
230
220
230
240
Free
setting
1-4
Setpoint AIR [°C]
260
260
260
260

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis