Commissioning/start-up
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Aquamax Eco Classic 3500/5500/8500/11500/14500/17500
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (Envi-
ronmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.

Remedy of faults

Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running period

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
 Clean the pump as required but at least twice a year.
 Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.
Cause
No mains voltage
Filter housing clogged
Excessively soiled water
Impeller unit blocked
Filter housing clogged
Excessive loss in the supply lines
Excessively soiled water
Water temperature too high
Impeller unit blocked
Pump has run dry
Remedy
 Check mains voltage
 Check supply lines
 Clean strainer casings
 Clean pump. The pump automatically
switches on again once the motor has
cooled down.
 Disconnect the power supply and remove
obstacle. Then switch the pump on again.
 Clean strainer casings
 Select larger hose diameter
 Adapt stepped hose adapter to hose diam-
eter
 Reduce hose length to reduce frictional
loss
 Avoid unnecessary connection elements
 Clean pump. The pump automatically
switches on again once the motor has
cooled down.
 Note maximum water temperature of +
35°C. The pump automatically switches on
again once the motor has cooled down.
 Disconnect the power supply and remove
obstacle. Then switch the pump on again.
 Flood pump. Fully submerge the unit when
operated in the pond.