9 Maintenance and cleaning
9 Maintenance and cleaning
9.1 Maintenance intervals
Daily
• Check level of anti-spatter agent and top it up
when required.
EN - 18
Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Cut the power to the work area of the robot.
• Switch off the power source.
WARNING
Risk of injury
Physical injury due to skin or eye contact with anti-spatter fluid being
expelled suddenly.
• Depressurise the Front Injector TMS-VI.
• Wear protective gloves and safety goggles.
NOTICE
• Maintenance and cleaning work may only be carried out by qualified
personnel (in Germany see TRBS 1203).
• Always wear your personal protective equipment when performing
maintenance and cleaning work.
NOTICE
• The specified maintenance intervals are guidance values and refer to
single-shift operation.
When using arc welding equipment, always observe the provisions of
EN 60974-4 Inspection and testing, as well as any national laws and
regulations.
Check the following:
Weekly
• Remove welding spatter.
Front Injector TMS-VI