7 Operation

7 Operation
EN - 16
CAUTION
Risk of slipping due to lubricant film
Atomized anti-spatter fluid deposits on the floor.
• Keep the workplace clean.
• Wear safety shoes.
CAUTION
Risk of slipping, tripping or falling
Risk of slipping, tripping or falling due to trailing cables.
• Select a site with a short approach distance in the work area.
• Remove the relevant safety hazards.
• Wear safety shoes.
NOTICE
• The Front Injector TMS-VI may only be operated by qualified personnel
(in Germany, see TRBS 1203).
• Please also consult the operating instructions for the welding
components, such as torch cleaning station, power source, etc.
 Fig. 3 Functional description on page EN-10
1 After cleaning, position the welding torch with the gas nozzle (2) vertically
above the Front Injector TMS-VI.
 Fig. 4 Putting into operation on page EN-12
2 Activate the 5/2 directional valve (4). The spraying operation is activated.
Recommended signal time approx. 1 sec.
3 After the spraying operation, integrated the welding torch in the welding
sequence.