Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel TMS-VI Betriebsanleitung Seite 37

Front injektor
Vorschau ausblenden Andere Handbücher für TMS-VI:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Front Injector TMS-VI
8 Putting out of operation
8.1 Disconnect the power supply
8.2 Drain the system
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
possible damage.
• Replace any damaged, deformed or worn parts.
• Wear protective gloves and safety shoes.
NOTICE
• As the Front Injector TMS-VI is integrated into a welding system, the
process for putting it out of operation depends on the robot control
system. Please make sure that the shutdown procedures for all
components integrated in the welding system are strictly observed.
1 Switch off compressed air.
2 Switch off the power source.
WARNING
Risk of injury
Physical injury due to skin or eye contact with anti-spatter fluid being
expelled suddenly.
• De-pressurize the Front Injector TMS-VI.
• Wear protective gloves and safety goggles.
8 Putting out of operation
EN - 17