Technical data

Table I: Nominal data
POWER INPUT (WATT)
Unit
40KQM012
40KQM015
Table II:

Material supplied

Table III: Operating limits
Cooling / Heating
Main power supply
Table IV: Components required for a complete installation
Name
Connection pipe
Wall sleeve
Wall cap
Finishing tape
Fastening tape
Tube insulation
Drain hose
Sealer putty
- Electrical connecting cable
between indoor and outdoor unit
Heat pump
Cooling
Heating
60W
60W
95W
95W
Description
Installation instructions
Owner's Manual
Fresh air intake baffle
Refer to outdoor unit installation manual.
Nominal single-phase voltage
Operating voltage limits
40KQM012 Ø (3/8") 9.52mm (Gas) / Ø (1/4") 6.35mm (Liquid)
40KQM015 Ø (1/2") 12.7mm (Gas) / Ø (1/4") 6.35mm (Liquid)
PVC film
I.D. 16 - 17 mm
1. Cable type:
according to EN 60335-2-40 standards.
Note:
For power supply wire size and delay type fuses, refer to the outdoor unit
installation instructions.
Specification
H07RN-F
, synthetic rubber insulation with Neoprene coating,
Quantity
Use
1
Indoor unit installation
1
Correct use
1
Air renewal
230V ~ 50Hz
min. 198V – max. 264V
220V ~ 60Hz
min. 198V – max. 242V
E N G L I S H
GB - 3