CONNECT TO THE WATER SYSTEM

-
For the connection of hot water, the mixed
version comprises 2 threaded ports 1/2 gas
15/21 F situated at the base, as well as a purge
-
stipulated on the diagram below
stipulated on the diagram below
stipulated on the diagram below.
WALL
CONNECTION
GROUND
CONNECTION
SIDE VIEW
Before connecting the device to the heating circuit drain the liquid
from the device by removing the plugs on the entry and exit connec-
tion.
The liquid can be put into the drain without any problem.
Threaded ports
1/2 GAS 15/21 F
500/750/1000W : 102 min-109 max
1750W : 115 min-122 max
Dimensions in mm
WATER INLET
1/2 GAS 15/21 F
500/750/1750W : 332.5
1000W : 372.5
FRONT VIEW
47
b
a
MIDDLE OF THE DEVICE
WATER OUTLET
1/2 GAS 15/21 F
137,5