Rev. 00 - 06/2014 - Instruction manual Compressor C 330/04 - C330/10 - C330/10+10 - C330/100
All activities carried out to ensure use and operation of the appliance, via various intervention types (regulation, valve
checks, cleaning of air filters, etc.) executed by the Manufacturer's technicians according to preestablished time intervals
and in the instance of faults or wear and tear.
in tHE inStanCE oF EXtRaoRDinaRY MaintEnanCE, tECHniCal aSSiSStanCE PRoViDED BY tHE Ma-
nUFaCtURER oR tHE aUtHoRiSED SUPPliER MUSt BE REQUEStED.
When disposing of the appliance, current legislation in force must be considered.
Dispose of the various component materials separately (plastic, copper, iron, etc.).
in tHE inStanCE oF EXtRaoRDinaRY MaintEnanCE, tECHniCal aSSiSStanCE PRoViDED BY tHE Ma-
nUFaCtURER oR tHE aUtHoRiSED SUPPliER MUSt BE REQUEStED.
USinG UnoRiGinal REPlaCEMEnt PaRtS iS FoRBiDDEn.
The following table displays various scenarios which may occur when using the appliance.
aUtHoRiSED oPERatoRS MUSt onlY CaRRY oUt oPERationS FoR WHiCH tHEY aRE QUaliFiED anD
WitH tHE ConSEnt oF tHE SaFEtY ManaGER (WHERE tHE aPPlianCE iS USED in a BUSinESS ContEXt).
ABNORMALITIES
The appliance will not
start or it stops and will
not re-start.
The appliance restarts
numerous times even
without a utensil.
The utensil does not emit
air.
Fall of pressure in the air
tank.
26

ExTRAORDINARY MAINTENANCE

END OF SERVICE LIFE

REPLACEMENT PARTS

ANOMALIES - CAUSES - SOLUTIONS

CAUSE
No electrical supply.
Intervention of thermal
reset owing to voltage over-
load and/or a short-circuit.
Leakages from the air pipe,
utensil or pneumatic sy-
stem.
The tank is not pressurised. • Switch on the appliance and wait until the tank fills checking
Incorrect regulation of the
outlet pressure.
The utensil is damaged.
Leakages in the air pipe,
utensil or the pneumatic
system.
SOLUTION
• Check that the "ON-OFF" switch (3) is in the "ON (I)" position.
• Check that the electrical plug is functioning correctly and
is correctly plugged in.
• Check that any extensions used and the plug are functio-
ning correctly.
• Check that the electrical main switch is functioning and in
the "ON" position.
• Carry out the procedure described in Paragraph "RESET
INTERVENTION – ThERMAL RESTORE".
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensils are intact as well as the
connections.
the pressure of the relevant gauge.
• Check that the value displayed on the outlet pressure gauge
(7) is greater than 0 (zero) bar.
• Check that the utensil is intact and effective.
• Check that the pneumatic system is not damaged.
• Check that the air pipe and utensil are not damaged.
• Check that the appliance-air pipe and air pipe-utensil con-
nections are correct.
• Check that the condensate pump is securely closed (5).