Herunterladen Inhalt Inhalt Diese Seite drucken

Operation And Maintenance - simu DMI5 Hz Originalanleitung

Vorschau ausblenden Andere Handbücher für DMI5 Hz:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Cancelling programming
9
9.1 - Switch off the power supply to the motor for 2 seconds.
9.2 - Switch the power to the motor back on for 7 seconds.
9.3 - Switch off the power supply to the motor for 2 seconds.
9.4 - Switch the power to the motor back on. The motor will run for 5
seconds in random direction.
The motor is now in the "cancelling" mode
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must "eject" out
of this mode all the receivers that are not to be deleted by sending a command from their individual control transmitter
(UP or Down).
9.5 - Then, confirm the cancelling of the concerned motor from the individual control:
- Press the PROG key of the transmitter more than
7 seconds. Maintain the pressure until the motor will first
run for 0,5 second in one direction and then in the other.
The motor is now as it was originally configured, and no transmitter and no settings is saved in its memory and is ready for a
new programming.

Operation and maintenance

10
- This drive is maintenance-free.
- Press the ▲ button on the control point to lower the motorised product.
- Press the ▼ button on the control point to raise the motorised product.
- If the motorised product is moving, briefly press the Stop button. The motorised product stops automatically.
Tips and recommendations for use:
OBSERVATIONS
he driven product does not operate.
T
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz
and used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives
and in particular of the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at www.simu.com. Emmanuel CARMIER, general director, GRAY, 11/2016.
5/5
POSSIBLE CAUSES
The drive's overheating protection on the
drive has tripped.
OFF
ON
OFF
2s.
7s.
1
PROG > 7s.
SOLUTIONS
Wait for the drive to cool down.
5s.
ON
2s.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dmi6 hz

Inhaltsverzeichnis