Press this key to select an operating mode .
3
-key
Use these keys to select the fan speed .
4
/
The selection keys can be used to select a Timer or
Temperature setting .
5
-key
Press this key to switch the Sleep mode on/off .
6
-key
Press this key to activate the power on/power off time .
Changing the battery
• Placing the batteries in the battery compartment.
1 . Remove the battery compartment lid .
Slide the battery compartment lid backwards away
from the unit .
2 . Place the new batteries into the battery compartment .
Please ensure that the poles are properly aligned .
3 . Close the battery compartment .
NOTE:
1 . The positive pole and the negative pole of the bat-
tery must be aligned with the "+" and "–" signs on
the remote control .
2 . Do not use new batteries together with old ones .
3 . Remove the batteries from the battery compart-
ment when you are planning on not using your unit
over a longer period of time .
en
operating manual – pac 2000 s moBile air conditioning unit
4 . Please make sure that you dispose of your old bat-
teries in a safe and proper manner . By doing so you
are providing a valuable contribution towards pro-
tecting and saving the environment .
Using the Remote Control
Point the remote control at the unit's signal receiver
to operate the unit . When used correctly, the remote
control will send signals to the unit over a distance of
7 metres (23 feet) .

Overload Protection

Operating Status
The unit powers off automatically when the automatic
overload protection is activated in the following cases:
Cooling
The room temperature is over
43 °C (109 °F)
The room temperature is lower
than 15 °C (59 °F)
Dehumidifying
The room temperature is lower
than 15 °C (59 °F)
When the air conditioner runs in cooling or drying
mode over a longer period when a window is open
and the relative humidity is more than 80%, then con-
densation can form at the outlet .
Operation of the overload protection
In the following cases the overload protection was
activated:
1 . At a restart when the appliance was switched off
before or the mode was changed while it operated .
Here you have to wait 3 minutes .
2 . When the unit is unplugged, the unit returns to the
original mode . The Timer has to be reset .