Installation and connection

Use as a fountain pump
PondoVario 750/1000
How to proceed:
 B
1. Assembling the telescopic extension: Insert the internal pipe into the external pipe and secure with the retaining col-
lar.
2. Insert the telescopic extension into the transition piece.
3. Insert and screw the desired nozzle into the telescopic extension.
4. Screw the telescopic extension with transition piece onto the pump and hand-tighten.
5. Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely cov-
ered with water.
PondoVario 1500/2500/3500
How to proceed:
 C
1. Assembling the telescopic extension: Insert the internal pipe into the external pipe and secure with the retaining col-
lar.
2. Fit the telescopic extension onto the ball joint.
3. Ensure that the control valve on the telescopic extension and the outlet of the ball joint are aligned opposite each
other so that water can exit from the outlet of the ball joint.
– Ensure that the control valve on the telescopic extension and the outlet of the ball joint are aligned opposite each
other so that water can exit from the outlet of the ball joint.
– The adjustable outlet on the ball joint can be used for feeding a water course.
4. Insert and screw the desired nozzle into the telescopic extension.
5. Screw the ball joint onto the transition piece of the pump and hand-tighten.
– Vertically align the telescopic extension via the ball joint.
6. Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely cov-
ered with water.
Use as a water course pump or filter pump
PondoVario 1500/2500/3500
How to proceed:
 D
1. Screw the stepped hose adapter with O ring onto the transition piece of the pump and hand-tighten.
2. Actuate the engagement hooks on the filter housing.
3. Remove the strainer casing.
4. Place the unit in the pond on a horizontal, firm and sludge-free base and ensure that it is completely covered by wa-
ter.
5. Maximum installation depth: 2 m below the surface of the water.
Commissioning/start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Use as a fountain pump
After installation and connection, adjust the shape of the fountain by changing the screw-in depth of the nozzles.
PondoVario 750/1000
 E
 Turn the control valve on the telescopic extension to achieve the desired spray pattern.
PondoVario 1500/2500/3500
 F
 Turn the control valve on the telescopic extension to achieve the desired spray pattern.
 If necessary, turn the control valve on the ball joint to achieve the desired flow rate.