5. Maintenance / Cleaning
It is recommended to clean the KEMPER respiratory unit after each use. Check all parts to make sure no
damage has occurred.
Precautions:
• Always clean the respiratory unit in an open room or outside.
• Be aware of a harmful dust settled on some parts of the unit.
• Never use flammable cleaning liquids.
• Make sure no detergents get into the unit or into the air hose.
• It is recommended to use dish washing detergents without abrasives to clean the unit.
• Clean up each part with a damp cloth and dry it properly afterwards.
• The auto darkening electronic filters (if the system is equipped with the autodark
sensitive to liquids. Only dry cleaning is allowed.
6. Spare parts / Replacing spare parts
6.1 KEMPER autoflow
6.1.1 Filter
The KEMPER autoflow
time of the filter may vary according to the level of contamination of the environment where the system
is used in and the size of dust particles. A critical state of saturation is signalised by an alarm as
referred to in chapter 4.2.
For hygienic reasons the filter should not be used longer than approx. 180 hours.
Do not try to clean the filter in any way - it will be destroyed.
Changing the filter
1. To remove the top lid (the silver lid) put your index fingers and middle fingers into the gaps on both
sides between the body and lid of the unit.
2. Rest the thumbs against the top of the unit. Gently push the thumbs and fingers in the opposite
directions. ATTENTION! Do not use any tools for opening the lid.
3. To remove the filter, pull it out while turning it.
4. Clean the unit from dust and put the filter back in position by turning and gently pushing it until it sits
well on the body of the unit.
5. Cover the unit with the silver lid. Pay special attention to fixing the lid properly (on both sides).
6.1.2 Battery
Before the first use make sure the battery is fully charged. This will take approx. 10 - 14 hours.
To charge the battery only use the included electronic charger. The charging is controlled electronically
and will stop when the battery is fully charged.
Use the charger indoors only. Charging time depends on the type of battery, the charging state and the
surrounding temperature.
®
respiratory system
®
respiratory system is equipped with highly efficient class P3 filter. The life
®
hood) are very
19