3.1.2 KEMPER freshflow
After having received the KEMPER freshflow
complete and that no part is damaged by transportation or any other cause.
Content of package:
• KEMPER freshflow
®
• Heavy duty belt
• Air hose
• Manual for user
Depending on what system you chose, there is also a hood included in the package. This will be
stated on the package itself.
KEMPER also recommends the use of a compressed air conditioner to make sure that the incoming
air is hygienically clean and breathable.
3.2 Assembly
3.2.1 KEMPER autoflow
a. Attach the autoflow
®
b. Attach the air hose to the unit and connect it to the hood you want to use.
c. Turn on the unit by pressing the "on/off" button on the switch board. The green LED's show the
actual status of airflow regulation. By pressing either the left or the right arrow, the airflow can be
adjusted from 140 l/min up to 210 l/min. The autoflow
air flow according to the filter saturation and the battery state. Should changing the filter or charging
the battery become necessary an alarm will sound.
d. Check if alarm works (Chapter 7).
e. The battery state is indicated by the red LED's on the switch board. Press the left arrow-button for
more than 1 second to check the battery state. If necessary, charge the battery (No LED is lit).
f. The filter saturation is indicated by the yellow LED's on the switch board. Keep the right arrow-
button pressed for more than 1 second. The more diodes press the right arrow-button for more than
one second to check the filter state. If necessary change the filter (All LED's are lit).
g. After releasing the arrow-button the LED's turn back to indicating the airflow (green light).
3.2.2 KEMPER freshflow
a. Attach the freshflow
®
b. Attach the air hose to the unit and connect it to the hood you want to use.
c. Connect the KEMPER compressed air conditioner (to be ordered as an accessory) to the
compressed air system or directly to a compressor.
d. If you do not have an air conditioner, connect the KEMPER freshflow
the compressed air system.
e. Make sure the manometer on the unit shows a pressure in the green range (between 300 and
1000 kPa).
f. If the air conditioner is used, the length of the hose between the respiratory unit and the conditioner
should not exceed 6 m.
g. Check the air flow rate (Chapter 7).
®
respiratory system
®
respiratory unit
®
respiratory system
respiratory unit to the heavy duty belt and adjust it to your personal needs.
®
respiratory system
respiratory unit to the heavy duty belt and adjust it to your personal needs.
package it is necessary to check if the package is
1 pc
1 pc
1 pc
1 pc
®
respiratory system automatically adjust the
®
respiratory unit directly to
17