How you use an extern negative pressure meter together with the DC 2800c Rental:
1
Be sure of that both fi ne- and HEPA-fi lter is
placed proberly. Control that there is no da-
mage on the fi lters. Change damaged fi lter.
3
Start the machine and connect the external negative pressure meter without using any tool. Read
the meter.
4
If the meter show more than 6 kPa - clean the fi lters and messure again according to above.
5
If the meter still show more than 6 kPa - change the finefilter and messure again.
6
If the meter still show more than 6 kPa - change the HEPA-filter and messure again.
2
Disconnect the standard hose from the inlet.
3 kPa means clean fi lters. Th e machine is ready for use.
Under 6 kPa is OK. Th e machine can be used.
Over 6 kPa is bad. See No 4 below.