ALARM
cod. G19502880
USE AND MAINTENANCE
DESCRIPTION
ALARM: MODULE MCM OVERLOAD
ALARM: LOW/HIGH MOTOR SPEED
Indicates that the gear motor fails to reach
WKH URWDWLRQ VSHHG UHTXLUHG IRU GLVSHQVLQJ
WKH QHFHVVDU\ TXDQWLW\ RI SURGXFW
ALARM: SHAFT CONFIRMATION
,QGLFDWHV WKDW WKH PRWRU LV UXQQLQJ
EXW WKH URWDWLRQ VHQVRU LV QRW UHFHLYLQJ
SXOVHV
ALARM: ENCODER FAILURE
Indicates that the motor encoder does not
VHQVH DQ\ URWDWLRQ SXOVH
ALARM: LOW/HIGH FAN SPEED
Indicates that the fan speed is higher or
ORZHU WKDW WKH PLQPD[ WKUHVKROG VHW LQ
the system.
ALARM: CARDAN SPEED
Indicates that the sensor installed on the
KDUURZ GRHV QRW VHQVH DQ\ URWDWLRQ SXOVH
7KLV PHVVDJH DSSHDUV H[FOXVLYHO\ ZKHQ
the machine is in work position and the
WUDYHO VSHHG LV !.PK
ALARM: HOPPER LEVEL LOW
,QGLFDWHV WKDW WKH SURGXFW OHYHO LQVLGH WKH
KRSSHU KDV GURSSHG EHORZ WKH VHQVRU
detection point.
-
ENGLISH
SOLUTION
 &KHFN WKDW WKH PHWHULQJ XQLWV DQGRU
PRWRU WXUQ IUHHO\
 0RGXOH 0&0 PD\ EH PDOIXQFWLRQLQJ
 7KH PRWRU PD\ EH PDOIXQFWLRQLQJ
 5HGXFH RU LQFUHDVH WKH WUDYHO VSHHG
 &KHFN WKDW WKH PHWHULQJ UROOHU LV VXLWDEOH
IRU WKH W\SH DQG TXDQWLW\ RI SURGXFW WR
EH GLVSHQVHG
 7KH PHWHULQJ XQLW LV VWXFN
 7KH DOXPLQLXP SLQ FRQQHFWLQJ WKH D[LV
DQG PHWHULQJ XQLW LV VKHDUHG
 7KH VHQVRU GHWHFWLQJ PHWHULQJ XQLW URWD-
WLRQ LV PDOIXQFWLRQLQJ GLVFRQQHFWHG RU
RXW RI SRVLWLRQ
- The encoder may have failed.
 7KH HQFRGHU FRQQHFWLRQ PD\ EH EURNHQ
 5HGXFH RU LQFUHDVH WKH IDQ VSHHG
 &KHFN WKDW WKH PLQPD[ DODUP WK-
UHVKROG LV VHW FRUUHFWO\ VHH VHFWLRQ
 
- The PTO is not connected.
- The safety device on the cardan shaft
KDV WULSSHG KDUURZ EORFNHG 
 7KH KRSSHU LV UXQQLQJ RXW RI SURGXFW