Herunterladen Inhalt Inhalt Diese Seite drucken

Siko MA01/1 Benutzerinformation Seite 16

Magnetbandanzeige
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

_dP_
decimal point (only if resolution has
been programmed "FrEE") 0. to 0.000
_dIR_
counting direction UP, dn
_dI_E
display of sensor inputs
CH_Add, CH
_A_SEn autom. channel switching (only if
'_dI_E' has been programmed to
"CH") on , oFF
_AUto_ switch-off method 0, 1, 2
PErIod switch-off time (in seconds) (only for
switch-off methods '1', '2') ... 999
_rSTo__ last value memory on , oFF
_F_AbS access reset function: on , oFF
_F_rEL access increm. measurement:
on , oFF
_F_rEF access reference value:
on , oFF
_F_oFF access offset value:
on , oFF
_LAn_
language d, E
1 6
MA01/1
Datum 16.11.2001
Art.Nr. 77320
– •
0.0
– •
UP
– •
CH
– •
oFF
0
009
oFF
• –
on
oFF
• –
oFF
• –
oFF
d
SIKO GmbH
Dr.-Ing. G. Wandres
Werk / Factory:
Weihermattenweg 2
D-79256 Buchenbach
Postanschrift / Postal address:
Postfach 1106
D-79195 Kirchzarten
Telefon / Phone 0 76 61 / 3 94 - 0
Telefax / Fax
0 76 61 / 3 94 - 388
eMail
info@siko.de
Internet
www.siko.de
Z.Nr. 8664054
Änd.Stand 389/01

Werbung