Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Siko MA01/1 Benutzerinformation

Magnetbandanzeige
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fig. 3: Sketch to show mounting EG30
Bench housingTGL
The rubber feet can be removed to enable the
unit to be screwed down.
Attention ! Max. reach of screw is 4.5 mm!

4. Electrical connection

• Switch power off before plugs are inserted or
removed!
• Wiring must only be carried out with power off!
• Provide stranded wires with ferrules.
• Check all lines and connections before swit-
ching on the equipment.
• If MA01/1 is used in combination with drive
systems, you must provide additional safety
protection, eg. limit switches.
• Movements or displacements during power
loss are not recognized / captured. Applications
with last value memory need a defined reference
value for correcting movements during power
loss accordingly.
Interference and distortion
All connections are protected against the effects
of interference. The location should be selec-
ted to ensure that no capacitive or inductive
interferences can affect the display or the
connection lines! Suitable wiring layout and
choice of cable can minimise the effects of
interference (eg. interference caused by SMPS,
motors, cyclic controls and contactors).
Necessary measures:
• Only screened cable should be used. Wire
cross section is to be at least 0,14 mm², max. 0,5
mm²
• Wiring to screen and to ground (0V) must be
1 0
MA01/1
1
2
3
Datum 16.11.2001
Art.Nr. 77320
via a good earth point having a large surface area
for minimum impedance.
• The unit should be positioned well away from
cables with interference; if necessary a protec-
tive screen or metal housing must be provi-
ded. The running of wiring parallel to the mains
supply should be avoided.
• Contactor coils must be linked with spark
suppression.
Power supply
The power can be connected by either the pin plug
strip at the rear, by battery or by using a mains
connection cable. The correct supply voltage is
indicated in the delivery documentation.
Desig. Description
(EG)
+
U
= 10 ... 30 VDC
B
GND
REF
reference input
Other TGL versions:
U
= 4.5 ... 10 VDC
(accumulator operation)
B
U
= 110VAC
-15%...+10% (main plug US-Norm)
B
U
= 230VAC
-10%...+6% (main plug with grounding contact)
B
Sensor connection
via 9-poles rear side SUB-D sockets.
Attention! No modifiction of the sensor connec-
tion is permitted or the max. admissable cable
length must not be exceeded. Please also read
User Information supplied with magnetic sensors.
Fig. 4: EG60, 2 sensors
Fig. 5: EG30, EG60, 1 sensor
Z.Nr. 8664054
Color
(TGL)
brown
white
green
Änd.Stand 389/01