Installation
GB
14
20.
Mount a new gas valve (standard delivery) with
seals on the gas connection tube and on the gas
supply line (14)
Note: To facilitate installation with gas condensing
boilers of series WGB 70 D and WGB 70 E, the gas
connection tube can be slightly moved horizontally
by loosening the screw (C). The screw must be re-
tightened after mounting the gas valve.
21.
Plug in the ignition cable, ionisation line and
ground wire in the ignition and ionisation unit
connections
22.
Plug the electrical connection lines on the connec-
tions on the fan
24. Attach new hose for fan pressure on the gas valve
(left image) and on the fan (right image) (16)
18
C
16
Gas valve for Paramount 80/Paramount two 80/Paramount three 80
15
23. Plug the electrical connection lines on the connec-
tions on the gas valve
Important! The grey plug for the gas pressure moni-
tor must be pulled out of the plug housing and rota-
ted by 180° before plugging on the gas valve (15).
D
E
25. Set CO
-contents according to the installation man-
2
ual (Allen key 2 mm)
(D): Full load
(E): Low load
180°
7314280-05 12.14