Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel ABIMIG A 255 Betriebsanleitung Seite 35

Vorschau ausblenden Andere Handbücher für ABIMIG A 255:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
ABIMIG
5.5 Attaching the cable assembly on the machine side
5.6 Connecting the coolant
1
Control lead
2
Coolant supply hose
Fig. 6
Connecting the coolant
 Fig. 3 Mounting the liner for ABIMIG
1 Join the central connector (7) and the central socket at the wire feeder.
2 Use the connection nut (5) to secure both of these.
3 Attach the cooling water supply and return connectors to the
®
ABIMIG
W / W T.
4 Attach the shielding gas and control lead connectors in the case of other
machine connections.
WARNING
Risk of burns
The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
1
3
Coolant recirculator
®
W T torches on page EN-10
2
3
4
4
5 Putting into operation
Coolant return hose
EN - 15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis