5.4 Attaching the wire guide
5.4.1 Liner
®
ABIMIG
A LW/ABIMIG
®
ABIMIG
A T LW
5 Screw together the gas nozzle (1) and the spatter protector (2).
The spatter protector (2) moves into the correct position within the gas
nozzle (1).
NOTICE
• To ensure a secure shielding gas cover, only use gas-tight, plastic-
insulated wire guides.
• Bare liners give rise to a loss of shielding gas.
NOTICE
• New and unused liners must be abridged to the actual length of the
cable assembly.
• If the torch has a fixed torch neck, only through-hole liners are used.
• To install the wire guide with a little preload, excess length is required.
• The sealing plug makes it easier to detach and attach the insulating piece
®
for ABIMIG
W T.
®
W
For use of steel wires with undivided wire guide.
1 Stretch out the BIKOX
contact tip from the torch neck.
2 Unscrew the nut from the central connector or direct connector and slide the
liner through the BIKOX
3 Screw down the nut again, tighten using an ABIMIG
excess length of the liner flush with the tip adaptor.
4 Screw in contact tip and gas nozzle.
For use of steel wires with divided wire guide.
1 Stretch out the BIKOX
contact tip from the torch neck.
2 Unscrew the nut from the central connector and slide the liner through the
®
BIKOX
/cable assembly up to the retaining nipple.
®
/cable assembly and unscrew the gas nozzle and
®
/cable assembly up to the retaining nipple.
®
/cable assembly and unscrew the gas nozzle and
5 Putting into operation
®
wrench and cut off