MAXIMUM PRESSURE SCREW
The maximum hydraulic pressure
was set before the log splitter left
the factory and the max pressure
limiting screw sealed. The setting
was done by a qualified mechanic
with professional instruments.
Unauthorised resetting will void
the warranty, may damage the
machine and could result in
serious injury.
This log splitter is equipped with
a control system that requires
operation by both hands of the
user — Left hand controls the
hydraulic control lever while right
hand controls the push button
switch. The log splitter will freeze
upon absence of either hand.
Only after both hands release the
controls, will the log pusher start
to return backward to the starting
position.
A trigger type lock-out device is adopted to avoid accidental Hydraulic
Control Lever pushdown. To operate the Hydraulic Control Lever, draw
the Trigger backward with the index finger before pushing the Hydrau-
lic Control Lever forward.
WARNING: DO NOT ADJUST THE MAX PRESSURE
LIMITING SCREW UNLESS AUTHORISED TO BY FOREST
MASTER. THIS MAY RESULT IN SERIOUS INJURY AS WELL
AS DAMAGE TO THE MACHINE.