PURPOSE OF FUSE: The purpose of this fuse is to protect the pump from serious damage in the
event of system blockages, therefore please ensure all valves are fully open before operating the
pump.
If the fuse blows:
a) Check that all system valves/stop cocks are open
b) Check that the inlet and outlet ports are not blocked
c) Check that the rest of the system is not blocked
d) Check for reverse polarity connection
11.vii CONNECT SWITCHING CABLE
11.vii CONNECTING GULPER IC TO STRAINER IC (SEE FIG 1)
12. PLUMBING
13. INSTRUCTIONS FOR USE
Ensure that pump installation is thoroughly tested before
first use.
NOTE - These are all automatic or semi-automatic
applications - ensure that isolator switch is turned on.
BILGE APPLICATION
Gulper® IC with Strainer IC - Place finger over sensor area
to check pump is activated, remove finger and wait for the
pump to stop (45 seconds).
If switching cable must be fitted through
bulkhead, ensure a minimum hole diameter
25mm (1") is drilled.
Hole diameter
25mm (1")
Fig 8 - Connecting switching cable through
minimum
Connect the pre-wired Deutsch connectors on Gulper® IC
and Whale Strainer IC.
Fig 9. Connect Deutsch Connectors
Use 19mm (3/4") or 25mm (1") smooth bore
reinforced pipework to connect to the pump.
Secure the pipework on inlet and outlet with worm
drive hose clip (Fig 10)
bulkhead
Fig 10 Secure pipework
Fig 11 Testing