Herunterladen Inhalt Inhalt Diese Seite drucken

Parts List; Optional Extras - Whale Bilge IC series Montagehandbuch Und Bedienungsanleitung

Abwasserpumpen-sortiment
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
7. APPLICATION
Gulper® IC is designed for installation in recreational marine vessels only and operated on 12 or 24
V d.c. electrical supply only. If it is intended for use for any other purpose or with any other liquid, it
is the user's responsibility to ensure that the pump is suitable for the intended use and, in particular,
that the materials are fully compatible with the liquids to be used. The Whale Gulper® IC pump is
not recommended for domestic applications.
8. WARNINGS
This pump must not be mounted below the water line when connected to an
intake or outlet unless the system has a vented loop (see Fig 1).
Not suitable for pumping flammable liquids, diesel, chemicals etc. Suitable for
bilge water only.
NOTE: Bilge pump capacities may not be sufficient to prevent flooding from rapid
accumulation of water due to storms, rough weather and/ or rapid leaks created by hull
damage and or unsafe navigational conditions.
With all applications, it is important that a system of safe working practice is applied to
installation, use and maintenance. Ensure the electric supply is turned off and waste water
system is drained before installation. In order to securely fasten the unit, ensure that the
mounting surface is a minimum thickness of 19mm (3/4") (when fitted with the screws
supplied).
NOTE Do not screw directly to the hull - must be mounted on a bulkhead or on an additional
board.
NOTE - DO NOT unscrew the rear section, as interference with the internal electrics will
render the pump unfit for use. - this is a non-serviceable part of the pump.
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include
a properly rated fuse or circuit breaker (See section 11v.) Improper wiring can cause a fire
resulting in injury or death. Switch off the power while making connections.
Suggested wiring information is given as a guide only. For full information, refer to the USCG, ABYC
and ISO regulations for marine applications and wiring gauges, connectors and fuse protection.
Contact Whale® Support team for further technical advice +44 (0)2891 270531 or email:
info@whalepumps.com

9. PARTS LIST

Qty 1
Gulper® IC bilge pump
Qty 3
No.8 self tappers and washers

10. OPTIONAL EXTRAS

AK2050 - Service kit - Replacement head for all Gulper® pumps
AK2086B - Deutsch® Connector Extension Cable 6m (18ft)
11. INSTALLATION
NOTE: Incorrect installation will invalidate warranty
Preparation - Always disconnect power sources before installing.
11.i Location
Choose a position to mount the pump that is dry and away from standing water and is free
from obstacles.
Mount in a position with the shortest possible pipe run lengths.
11.ii Mounting Instructions - Gulper® IC
Gulper® IC can be mounted on a horizontal or vertical surface.
When mounted vertically ensure that the pump head is lower most (see Fig 2).
Qty 1
Strainer IC
Qty 1
Inline fuse assembly
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis